AMD Geode™ SC2200 Processor Data Book
119
SuperI/O Module
32580B
1
Hour Mode.
This bit is reset at V
PP
power-up reset only.
0: Enable 12-hour format.
1: Enable 24-hour format.
0
Daylight Saving.
This bit is reset at V
PP
power-up reset only.
0: Disable.
1: Enable:
- In the spring, time advances from1:59:59 AM to 3:00:00 AM on the first Sunday in April.
- In the fall, time returns from 1:59:59 AM to 1:00:00 AM on the last Sunday in October.
Index 0Ch
RTC Control Register C - CRC (RO)
Reset Type: Bit Specific
7
IRQ Flag.
Mirrors the value on the interrupt output signal. When interrupt is active, IRQF is 1. To clear this bit (and deacti-
vate the interrupt pin), read the CRC Register as the flag bits UF, AF and PF are cleared after reading this register.
0: IRQ inactive.
1: Logic equation is true: ((UIE and UF) or (AIE and AF) or (PIE and PF)).
6
Periodic Interrupt Flag.
Cleared to 0 on RTC reset (i.e., hardware or software reset) or the RTC disabled. In addition, this
bit is cleared to 0 when this register is read.
0: No transition occurred on the selected tap since the last read.
1: Transition occurred on the selected tap of the divider chain.
5
Alarm Interrupt Flag.
Cleared to 0 as long as bit 7 of the CRD Register is reads 0. In addition, this bit is cleared to 0 when
this register is read.
0: No alarm detected since the last read.
1: Alarm condition detected.
4
Update Ended Interrupt Flag.
Cleared to 0 on RTC reset (i.e., hardware or software reset) or the RTC disabled. In addi-
tion, this bit is cleared to 0 when this register is read.
0: No update occurred since the last read.
1: Time registers updated.
3:0
Reserved.
Index 0Dh
RTC Control Register D - CRD (RO)
Reset Type: V
PP
PUR
7
Valid RAM and Time.
This bit senses the voltage that feeds the RTC (VSB or VBAT) and indicates whether or not it was
too low since the last time this bit was read. If it was too low, the RTC contents (time/calendar registers and CMOS RAM) is
not valid.
0: The voltage that feeds the RTC was too low.
1: RTC contents (time/calendar registers and CMOS RAM) are valid.
6:0
Reserved.
Index Programmable
Date of Month Alarm Register - DOMA (R/W)
Reset Type: V
PP
PUR
7:0
Date of Month Alarm Data
. Values may be 01 to 31 in BCD format or 01 to 1F in Binary format.
When bits 7 and 6 are both set to one (“11”), unconditional match is selected. (Default)
Index Programmable
Month Alarm Register - MONA (R/W)
Reset Type: V
PP
PUR
7:0
Month Alarm Data.
Values may be 01 to 12 in BCD format or 01 to 0C in Binary format.
When bits 7 and 6 are both set to one (“11”), unconditional match is selected. (Default)
Index Programmable
Century Register - CEN (R/W)
Reset Type: V
PP
PUR
7:0
Century Data.
Values may be 00 to 99 in BCD format or 00 to 63 in Binary format.
Table 5-20. RTC Registers (Continued)
Bit
Description
Summary of Contents for Geode SC2200
Page 8: ...8 AMD Geode SC2200 Processor Data Book List of Figures 32580B...
Page 16: ...16 AMD Geode SC2200 Processor Data Book Overview 32580B...
Page 70: ...74 AMD Geode SC2200 Processor Data Book Signal Definitions 32580B...
Page 350: ...366 AMD Geode SC2200 Processor Data Book Debugging and Monitoring 32580B...
Page 422: ...440 AMD Geode SC2200 Processor Data Book Electrical Specifications 32580B...