IT IS possible to associate different report codes to different telephone numbers. 

The list of the default events follows below: (all the events are changeable)

C01 - ALARM line 1 (EVENT 130)
C02 - ALARM line 2 (EVENT 130)
C03 - ALARM line 3 (EVENT 130)
C04 - ALARM line 4 (EVENT 130)
C05 - ALARM line 5 (EVENT 130)
C06 - TAMPER line 1 (EVENT 137)
C07 - TAMPER line 2 (EVENT 137)
C08 - TAMPER line 3 (EVENT 137)
C09 - TAMPER line 4 (EVENT 137)
C10 - TAMPER line 5 (EVENT 137)
C011 - LIFE TEST (EVENT 602)
C012 - GSM KO (EVENT 351)
C013 - CARD TAMPER (EVENT 137)

Once you have accessed the menu, press 

ENTER

, with the 

up

 and 

down

 arrow keys choose the desired event, then press ENTER 

again use the 

rh

 and 

lh

 arrows to position yourself on the telephone number to be associated, press 

CANCEL

 to include or exclude 

the selection and confirm with 

ENTER

CONTACT ID MENU: ASSOCATE TELEPHONES

SIM CREDIT INFO MENU

This menu is used to program the values for the request of the credit exhaustion and of the SIM expiration.

The parameters are:  - phone number – SMS TExt- Keyword.

For The main Italian providers the parameters are already set. For the other providers, it’s needed to set phone number/keyword /

SMS text to send to the provider.

Note

: it’s possible to use a KEYWORD  to identify the value for credit to visualize on display. This word MUST COME  first of  the 

value indicated in SMS received from the provider.
Example:   

SMS TEXT=  “Traffic of  2,33 euro.....” can be used Traffic.

 

 

SMS TEXT= “Credit available= euro 2,33.....” can be used Credit.

It’s possible also to activate the request for SIM EXPIRATION, only for the providers that offer this service.

In this exampleTim E Wind are enabled
It is also possible to program a low credit threshold, below which the dialer makes a call and/or sends and SMS.

NOTE

: DON’T USE BOTH the functions LOW CREDIT and SMS ECHO . This in order to avoid the reception of low credit from both 

the GSM provider and the dialler.

ENABLE 

        TVWA

SIM EXP.   

      

  

 

CREDIT THRESHOLD 

  [EURO]                     5 

TEST MENU

It’s possible to test the capacity of the dialler to call (vocal call or contact id). To make the test you need only to insert the phone 
number (first position in phone book) to call in the phonebook (vocal/contact id).

Test -- Vocal Call

                    Call status:

NOT READY 

–  the dialler is not able to call (example: not registered to GSM)

CALLING

  

–  the dialler is calling the number desired

RING 

   

–  the number set is ringing

ONLINE 

 

–  online

To exit from the test phase, press the key #

Summary of Contents for VOXOUT

Page 1: ...ith voice guidance local programming from keyboard remote programming via sms output enabling via ring with confirmation ring 5 selectable lines that can be freely programmed as inputs or outputs Doub...

Page 2: ...level 3 without the authorization of users at level 2 NOTE for CIE with grade upper to 1 and or when there are 2 or more inputs like robbery the device of tran smission of alarms can not be used avail...

Page 3: ...e duration Of the outgoing calls CANCEL x TO RECORD ENTER V TO LISTEN AGAIN Time in sec between one attempt and the next call attempt Call attempts made in case phonecalls have not been successful Num...

Page 4: ...ated output the output must have function U OUTPUT MENU Function Pulse duration Associate Telephones USER CODE MENU User types 01 User Nr 01 M Program Codes CODE User Nr xx 111111 default UT01 Reset C...

Page 5: ...hold EURO 3 MENU VARIOUS PARAMETERS Life Test 0 Answ Ring 3 Event Delay 5 Value expressed in hours Time in seconds of the inhibition of an input after a first opening Board Tamper 0 0 disabled 1 enabl...

Page 6: ...n assigned CHANGE PERSONAL CODE CODE User No xx 111111 Cod USER DEFAULT 111111 01 Line 01 D Key to enable outputs Key to disable outputs Attention The functions Medical Aid key arrow left and Fire key...

Page 7: ...ose 1 to Enable Disable Out 2 Choose 1 to Enable Disable Out 5 Wait Input name enabled disabled System enabled reset closed System disabled reset open Incorrect OK Welcome Choose 1 to enable the envir...

Page 8: ...alarm relay is connected to input 1 the OPEN COLLECTOR 1 output is configured as the absence of an electrical netwrok and is connected to input 2 SUPPLY power supply 13 8Vcc L 1 2 3 4 5 Lines inputs o...

Page 9: ...instead the system is updating the information with the provider By pressing the CANC X key again you will shift to the display if available of the entire SMS received from the Provider NOTE The avai...

Page 10: ...er supply press the key and keep it pressed to resume power supply The dialer will ask you to choose the language ITALIAN or foreign language and will then run the initialization and will restore all...

Page 11: ...menu With this option the user will not have to type in any code to access his menu C automatic reset of call que If the call to the telephone number with this option is successful the que of the rema...

Page 12: ...ates that our phone called by the dialer will ring for 30 seconds after which the dialer will hang up and will restart with the next call cycle We recommend a minimum value of 50 seconds NUMBER OF ATT...

Page 13: ...MENU OF OUTPUTS FUNCTION IT IS possible to program the output with the following functions output disabled A it is enabled by following the assoicated input only with reset terminal closed H it is en...

Page 14: ...NTER CONTACT ID MENU IDC AND SYSTEM NUMBERS IDC numbers It is possible to insert 8 telephone numbers to which send the report code Press ENTER insert the number confirm with ENTER with the up and down...

Page 15: ...t For the other providers it s needed to set phone number keyword SMS text to send to the provider Note it s possible to use a KEYWORD to identify the value for credit to visualize on display This wor...

Page 16: ...mediately sent out To re open the same input within the pro grammed10 seconds the second signal will not leave immediately but once the 10 seconds have lapsed Once you have accessed the menu press ENT...

Page 17: ...e the buzzer from the keys allow the installer to reprogram the dialer from remote USE OF THE SMS FOR PROGRAMMING PURPOSES The SMS to be sent must have a precise structure and must always be preceded...

Page 18: ...K OFF this command unlocks the programming via sms for 20 minutes 111111 is the default pwd If the installer must for example assign the type ALARM input to input 2 he will send an SMS giving his pass...

Page 19: ...TIME OF THE ATTEMPTS in seconds from 0 to 240 VOXREPEAT VOICE MESSAGE REPETITIONS max 9 VOXWAIT ANSWER WAIT in seconds from 0 to 60 RINGSNR RINGS BEFORE ANSWER max 10 OUTTEL ASSOCIATION OF TELEPHONES...

Page 20: ...in the case of limitations and or problems due to faultiness in the service offered by the network provider TECHNICAL SPECIFICATIONS Power supply 13 8Vcc 0 7 Vcc Current in standby 150mA Maximum curre...