Normally, when the microwave detector is inactive, +12 V is supplied at the „B/S” input of the detector via the 
1kΩ bias resistor from the OUT3 output 

By controlling the OUT5 output (shorting the output to ground), which is connected via the 1kΩ resistor, it 

is possible to force the " B/S " input to a low state, which turns on the microwave detector (when the system is 
armed). 

 

4. Lens     

 

 

 

Fig. 5a  

Sensor range - side view 

Fig. 5b 

Sensor range - top view 

 

5. Technical data 

 

MOUSE 01 

 

Power supply 

9÷15VDC 

Power consumption: Alarm / Standby 

26,0mA /18,5mA@13,8VDC 

Sensor range 

up to 14m 

Operating angle 

90° 

PIR Sensor 

2 components 

Lens 

29 areas in 5 levels 

Microwave frequency 

10.525GHz 

Emission of microwave signals 

1mW / impulses 

Alarm signaling time 

4s 

Alarm type 

AND / OR  

Tamper protection (opening of the detector) / detachment from 
the wall 

YES / YES 

Creep zone detection 

YES 

Maximum load of the contacts of the relay 

100mA@40VDC / 2,5-16Ω 

Maximum load of the contacts of the tamper 

40mA@30VDC 

Operating temperature 

-10°C÷55°C 

Storage Temperature 

-20°C÷60°C 

Electromagnetic immunity 
(radio frequency interference) RFI 

10V/m (80MHz-2000MHz) 

LED (walk test) 

YES 

Summary of Contents for MOUSE 01

Page 1: ...r operation is shown in the Figure 5a and 5b The anti masking function is based on the microwave sensor If the microwave sensor detects any object in a distance of several centimeters from the detector it is interpreted as an attempt to block the detector and causes the opening of the NC anti masking relay for about 2 seconds 2 Installation of the detector The detector should be mounted by a quali...

Page 2: ... with a description of the available functions can be found in the following pages 6 Close the lid of the sensor CAUTION When closing the cover of the detector check whether the spring of the micro switch tamper is correctly pressed into the tapered socket in the lid The field of view of the detector should not be partially or completely obstructed 7 Connect the supply voltage and wait until the L...

Page 3: ... the protected space Microwaves can penetrate gypsum walls doors etc which may generate false alarms 2 Three position ON OFF potentiometer selection of additional functions The following functions can be activated with the dip switch turning of the microwaves alarm memory DUO MASK function See description below in Table 1 Table 1 Elements of the detector configuration Dip switch switches Descripti...

Page 4: ...th PIR and WM detectors in case of intruder detection 3 The tamper disable jumper If the tamper indicating enclosure opening will be used in addition to the tamper indicating detachment from the wall remove the JP jumper Turning off the microwaves an example of use of the function The use of dual element detectors especially when using the PIR and MW detectors in the AND mode alarm by both detecto...

Page 5: ...1 Power supply 9 15VDC Power consumption Alarm Standby 26 0mA 18 5mA 13 8VDC Sensor range up to 14m Operating angle 90 PIR Sensor 2 components Lens 29 areas in 5 levels Microwave frequency 10 525GHz Emission of microwave signals 1mW impulses Alarm signaling time 4s Alarm type AND OR Tamper protection opening of the detector detachment from the wall YES YES Creep zone detection YES Maximum load of ...

Page 6: ... equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual It is necessary to periodically test the signaling device The majority of Intrusion Detection Systems indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the LCD keypad or LED light on the LED display In case of such situati...

Page 7: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...

Reviews: