5
Normally, when the microwave detector is inactive, +12 V is supplied at the „B/S” input of the detector via the
1kΩ bias resistor from the OUT3 output
By controlling the OUT5 output (shorting the output to ground), which is connected via the 1kΩ resistor, it
is possible to force the " B/S " input to a low state, which turns on the microwave detector (when the system is
armed).
4. Lens
Fig. 5a
Sensor range - side view
Fig. 5b
Sensor range - top view
5. Technical data
MOUSE 01
Power supply
9÷15VDC
Power consumption: Alarm / Standby
26,0mA /18,5mA@13,8VDC
Sensor range
up to 14m
Operating angle
90°
PIR Sensor
2 components
Lens
29 areas in 5 levels
Microwave frequency
10.525GHz
Emission of microwave signals
1mW / impulses
Alarm signaling time
4s
Alarm type
AND / OR
Tamper protection (opening of the detector) / detachment from
the wall
YES / YES
Creep zone detection
YES
Maximum load of the contacts of the relay
100mA@40VDC / 2,5-16Ω
Maximum load of the contacts of the tamper
40mA@30VDC
Operating temperature
-10°C÷55°C
Storage Temperature
-20°C÷60°C
Electromagnetic immunity
(radio frequency interference) RFI
10V/m (80MHz-2000MHz)
LED (walk test)
YES