AMC AUTOMATION CO.
P.8
5. Label Counter
This section was deleted for machine overview purpose.
6. Parameter Table
Parameter
Display / Description
Default value
P1
Label length
:
Length of each label in mm
75 mm
P2
Begin fold length
:
Fold length for 1 fold cutting
0 mm
P3
End fold length
:
Fold length for 2 fold cutting
0 mm
P4
Excess label length
:
End length cut off (mm)
0 mm
P5
Cutting force
:
Cutting force in 0 to 50 unit maximum
0
P6
Scoring force:
Scoring force in 0 to 50 unit maximum
0
P7
Use line sensor
:
Use the label pattern detection sensor
No
P8
Auto Search Color
:
Auto search between background and pattern contrast.
Select ‘no’ means manual position background and
pattern.
Yes
P9
Label count
:
Value of label counter at current lot
0
P10
Lot number
:
Current lot number
1
P11
Lot size
:
Number of labels for each lot
0 value will enable non-stop cutting and lot
number will increment by 1 for every 10,000 label
output
120
P12
Use auto magazine:
auto magazine function
(NO = not use; Yes = use)
Yes
P13
Label end detect
No
P14
Machine speed index:
Current machine speed index. Machine speed increase
as number increase.
4
P15
Sensor 1:DC 2:AC
DC= static sense. AC=dynamic sense
1
P16
Sense: 1 low 2 mid 3 high
Sensor sensitivity selection
2
P17
Light: Auto-R-G-B
0=Auto 1=Red 2=Green 3=Blue
0