background image

Corporate Head Office 
& Manufacturer:

Ambu A/S
Baltorpbakken 13
DK-2750 Ballerup
Denmark
Tlf. 

+45 72 25 20 00

Fax. 

+45 72 25 20 50

E-mail: [email protected]
www.ambu.com

USA

Ambu Inc.
6740 Baymeadow Drive
Glen Burnie, MD 21060
Maryland
Tel. 

+1 410 768 6464

 

+1 800 262 8462

Fax. 

+1 410 760 4907

www.ambu.com

France

Ambu S.A.R.L
Airspace — 6, Rue Gagarine
F-33185 Le Haillan
Tlf. 

+33 5 57 92 31 50

Fax. 

+33 5 57 92 31 59

www.ambu.com

Germany

Ambu GmbH
In der Hub 5
D-61231 Bad Nauheim
Tlf. 

+49 6032 92500

Fax. 

+49 800 ambude

www.ambu.de

UK

Ambu Ltd.
8 Burrel Road
St. Ives
Cambridgeshire PE27 3LE
Tel. 

+44 1480 498 403

Fax. 

+44 1480 498 405

www.ambu.com

Italy

Ambu S.R.L 
Via Paracelso, 18
Centro Direzionale Colleoni
20041 Agrate Brianza - Milano
Italia
Tel.: 

+39 039 657811

Fax: 

+39 039 6898177

www.ambu.it

Spain

Firma Ambu S.L.
C/ Alcalá 261-265, Edificio 1, 3º Izq
28027 Madrid
Tlf.  

+34 91 411 68 30 

Fax. 

+34 91 564 50 82

www.ambu.es

Netherlands

Ambu B.V.
Edisonstraat 16j
2809 PB Gouda
Tlf.  

+31 0182 573293

Fax.  

+31 0182 531364

www.ambu.nl

Pat. Pending

Ambu

®

 aScope™  

Ambu

®

 aScope™ Monitor

492 8400 00 - 04/2010 - 

Version 1.0.0

Ambu A/S

Baltorpbakken 13
DK-2750 Ballerup
Denmark
T   +45 72 25 20 00
F   +45 72 25 20 50
www.ambu.com

0086

Summary of Contents for aScope

Page 1: ...ns for use Ambu aScope For Single Patient use only Sterile For use by trained clinicians physicians only For in hospital use Ambu aScope Monitor For use by trained clinicians physicians only For in ho...

Page 2: ...800 ambude www ambu de UK Ambu Ltd 8 Burrel Road St Ives Cambridgeshire PE27 3LE Tel 44 1480 498 403 Fax 44 1480 498 405 www ambu com Italy Ambu S R L Via Paracelso 18 Centro Direzionale Colleoni 2004...

Page 3: ...to an external monitor video recorder 15 10 Clinical Application 15 11 Preparation for Use 15 12 Use of the Ambu aScope system 16 12 1 Injection and control of the Luer channel 17 12 2 Removal proced...

Page 4: ...loose parts or the bending section does not work as intended Do not touch the distal tip of the insertion cord or allow it to strike other objects The lens surface of the distal tip is fragile and vis...

Page 5: ...conventional cleaning and sterilization procedures 2 Intended Use The Ambu aScope is intended for use as an aid in the placement of an Endotracheal Tube ETT directly or through an intubating laryngea...

Page 6: ...e Ambu aScope Working length of the Ambu aScope insertion cord Maximum width of inserted portion Min ETT ID 6 mm Minimum ET tube inner diameter 6 0mm see section 12 Field of view Operating time of the...

Page 7: ...and electrical waste WEEE Only applicable for the Monitor Li ion Battery type Lithium ion Only applicable for the battery inside the Ambu aScope Monitor Re chargeable battery Only applicable for the...

Page 8: ...duct specifications Ambu aScope Optical System Field of View 80 Direction of View 0 forward viewing Depth of Field 2mm 50 mm 0 1 1 968 inch Illumination method LED LTW C282DS5 SE Insertion cord Distal...

Page 9: ...al standard NTSC Video out connection 3 5mm jack socket Video out cable 3 5mm jack plug to RCA jack plug Storage Temperature 10 40 C 50 104 F Relative humidity 10 90 Mounting interface Mounting interf...

Page 10: ...r battery icon on the screen changes from green fully charged battery via orange half battery capacity to red low bat tery capacity within 30 minutes it is recommended that the Ambu aScope Monitor is...

Page 11: ...t Function Material 1 Monitor frame PC Polycarbonate ABS Acrylonitrile Butadiene 2 Monitor screen Shows the picture from the camera Glass 3 Bracket Secures the monitor to e g an IV pole POM GF25 Polyo...

Page 12: ...sportation purposes Cardboard Table 5 Functions and materials 8 2 1 Monitor placement on the bracket The Ambu aScope Monitor can be placed on a flat surface But to secure the Ambu aScope Monitor it is...

Page 13: ...alf time left orange Time is expiring Less than 5 minutes left red Plug is connected and the monitor battery is above half charged green Plug is connected and the monitor battery is half charged orang...

Page 14: ...device should not be used A physician who is familiar with this device can perform the preparation for use in a time range of 1 4 minutes The tests should be conducted in a manner consistent with acce...

Page 15: ...tructions do not explain or discuss clinical intubation procedures They describe only the basic operation and precautions related to the operation of this Ambu aScope system Before initial use of the...

Page 16: ...rocedure turn the Ambu aScope off in between sessions and place it on a sterile surface Be aware of the total operating time limit of 30 minutes during a period of 8 hours from first switching on 12 3...

Page 17: ...d collection schemes for disposal of batteries In order to remove the battery use a Torx screwdriver to remove the battery lid 13 Trouble shooting guide If problems occur with the system please use th...

Reviews: