background image

 

50D0104 RCSTE  Rel 0  Feb 10 2006 

Page 2 of 7 

 Ambient Technologies

A Division Of Monessen Hearth Systems

 

 

This remote control system requires three (3) “AAA” batteries to power the transmitter and 120VAC to 
power the receiver.  Wiring must conform to appliance requirement and building codes/ordinances as 
required by local and national code authorities having jurisdiction. 

 

Do not short (or jumper) across the gas valve terminals to test the remote control installation. This could 
damage the unit and void the warranty. 

 

This remote control system should only be used as described in this manual.  Any other use is not 
recommended and will void the warranty. 

 
 

NOTE 

Due to the sensitive temperature monitoring components in the transmitter,  it is  necessary to 
allow the transmitter to stabilize to room temperature before accurate room temperatures are 
displayed.  If the transmitter is activated from a severe cold condition, allow 15 minutes for 
accurate temperature readings to appear on the LCD. 

 

 

WA

R

N

IN

G

 

Turn appliance OFF and allow to cool before installing or servicing.  DO NOT connect 
110-120 VAC wiring to the milli-volt gas control valve.  The remote operator must be installed 
exactly as outlined in these instructions.  Read all instructions completely before attempting 
installation.  Follow instructions carefully during installation.  Any modification of 
components will void the warranty and may cause a fire hazard.

 

 

W

A

RNING 

Turn appliance OFF (at the appliance or remote receiver) if you are away from your house 
for a long period of time.   

 

 

INSTALLATIONS 

 

Remote Receiver 

 
The remote receiver may be wall mounted or installed in the 
appliance per the appliance homeowner’s manual. Refer to the 
Homeowner’s Manual for special installation instructions.  If 
wall mounted, the remote receiver must be installed in a junction 
box with cover plate provided.  Failure to follow the installation 
instructions found in the appropriate Homeowner’s Manual will 
void the warranty and may cause a fire hazard. 
 
 
Power up Receiver 
 
The receiver is powered by plugging into a polarized 120VAC 
outlet. 
 

 

 
 
 
 

Receiver

mV Valve

120VAC Plug for Receiver

f i r e - p a r t s . c o m

Summary of Contents for RCSTE

Page 1: ...t unless all parts are in good condition Please keep this booklet for future reference CONTENTS OF KIT Description Qty Transmitter 1 Battery Alkaline AAA for Transmitter 3 Receiver Assembly consists of 1 Receiver Box Slide Button Black On RS Off Wall Cover Plate Black 1 Plug In Wiring Assembly 22 Inches 1 Velcro Loop and Hook 1 Installation Instructions 1 6 3 4 Screws Zinc for Wall Cover Plate 2 F...

Page 2: ...s to appear on the LCD WARNING Turn appliance OFF and allow to cool before installing or servicing DO NOT connect 110 120 VAC wiring to the milli volt gas control valve The remote operator must be installed exactly as outlined in these instructions Read all instructions completely before attempting installation Follow instructions carefully during installation Any modification of components will v...

Page 3: ... that the wires do not contact the appliances any place other than at the terminals Exposure to temperatures higher than 105C 250ºF may cause the receiver to malfunction or fire hazard Remote Transmitter Installing Batteries The remote transmitter uses three 3 AAA batteries To install batteries 1 Press down the battery door tab and lift up and remove the battery door 2 Install the batteries as ind...

Page 4: ...can be set to temperature ranges between 45 F and 90 F The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet The distance is reduced when batteries are low or when the receiver is inside a metal enclosure Initial Start up 1 After initial power up or when RESET button is pressed the transmitter is reset The reset button is located inside the battery door 2 During syste...

Page 5: ... minute When the battery voltage drops to a certain level the low battery warning will come on and the transmitter will turn off the appliance The transmitter will not function anymore until fresh batteries are installed 2 When the batteries are low the LCD shows a low battery indicator The low battery warning will be displayed in any mode 3 The transmitter will not operate with low batteries Chan...

Page 6: ...press the transmitter to turn the system to ON The main gas flame should ignite 5 Press the transmitter to turn the system to OFF The flame should extinguish the pilot light will remain on TROUBLESHOOTING Symptom Causes Action 1 Low battery icon on display on transmitter 2 Display is blank 3 Display shows funny display 1 Low Battery on Transmitter 1 Replace batteries Change batteries every 6 month...

Page 7: ... is connected Consult the dealer or an experienced radio TV technician for help WARRANTY This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province Answers to any questions regarding our limited warranty may be obtained by writing our corporate offices Ambient Technologies warrants each new Ambient Technologies remote cont...