Cleaning, maintenance and repair
•
Observe legal requirements when disposing of lubricants, e.g.
oils and grease. Also affected by these legal requirements are
parts that come into contact with these lubricants.
•
Do not exceed a greasing pressure of 400 bar when greasing
with high pressure grease guns.
•
The following are prohibited
ο
drilling the running gear.
ο
drilling through pre-existing holes on the transport frame.
ο
welding on load-bearing components.
•
Protective measures are necessary, such as covering lines or
removing lines in particularly critical locations
ο
during welding, drilling and grinding work.
ο
when working with cut-off wheels near plastic wires and
electric wires.
•
Clean the implement thoroughly with water before carrying out
repair work.
•
Always disconnect the implement cable as well as the power
supply from the on-board computer when performing any care
and maintenance work. This applies particularly to welding work
on the implement.
The implement may only be operated with the protective devices
equipped ex factory.
Hydraulic cylinders may only be opened by authorised persons.
•
The mounting category (pin diameter) for the three-point linkage
must be compatible for tractor and plough.
•
Special care must be taken when mounting or dismounting the
implement onto or from the tractor.
•
Prior to connecting and disconnecting the implement to the
three-point suspension, place operating equipment in such a
position as to prevent unintentional lifting or lowering.
•
Check the hydraulic hoses and connections regularly and keep
them in good condition.
•
Maintenance, repair, and adjustment work may only be carried
out when the implement has been lowered to the ground in
working position and the hydraulic system is depressurised.
Read the operating manual of the tractor manufacturer to find out how
to depressurise the system.
The stored energy in the hydraulic accumulator can lead to serious
injuries when working on the hydraulic system. Hydraulic pressures
up to 400 bar!
Only perform work on a depressurised system.
Hektor BAG0186.1 07.19