Attaching and removing the machine at the tractor's rear three-
point system
40
Groundkeeper Jumbo SMARTCUT BAF0008.3 05.17
5.4.3
Electrically controlled hydraulic block (optional, country-specific)
In order to be able to work correctly with the machine, the following
hydraulic joint must be fitted on the tractor side.
The remote control supplied with the machine is held in place in the
driver's cab by the holder provided and allows the machine to be op-
erated using only two hydraulic lines and one additional electrical
connection.
Connection 1: permanent pressure connection
required hydraulic power
:
200 bar
40 l/min
Connection 2: free return
max. return pressure
:
1.5 bar
Connection 3: electrical socket, 3-pin
required electrical power
:
12 V
15 A
If the tractor has no connection for the electrical system, an optional
additional cable with socket can be obtained from
.
CAUTION
If you connect this cable incorrectly to the battery the hydroelec-
tric control system may be severely damaged. Connect the cable
as follows:
(-) Earth = blue
(+) Voltage = brown