General safety instructions
28
Groundkeeper Jumbo SMARTCUT BAF0008.3 05.17
2.16.3
Electrical system
•
When working on the electrical system, always disconnect the
battery (negative terminal).
•
Only use the prescribed fuses. If fuses are used with too high a
rating, the electrical system will be destroyed – danger of fire.
•
Ensure that the battery is connected correctly - firstly connect the
positive terminal and then connect the negative terminal. When
disconnecting the battery, disconnect the negative terminal first,
followed by the positive terminal.
•
Always place the appropriate cover over the positive battery termi-
nal. Contact with earth may cause an explosion
•
Risk of explosion: avoid the production of sparks or the presence
of naked flames in the vicinity of the battery.
•
The machine can be equipped with electronic components and
units, whose function may be influenced by electromagnetic in-
terference from other devices. Such influences can lead to per-
sonal hazard if the following safety information is not followed.
ο
If electrical units and/or components are retrofitted on the
machine, which require a connection to the on-board power
supply, the user must assume responsibility for checking
whether the retrofit causes faults in the vehicle electronics
or in other components.
ο
Ensure that the retrofitted electrical and electronic compo-
nents comply with the EMC directive 89/336/EEC in the ap-
propriate version and carry the CE mark.