GreenDrill 5.2 on-board computer
GreenDrill BAH0054-4 02.13
51
7.6
Messages
7.6.1
Control messages
Fault message
Fault description
Fault elimination
The internal control voltage is
below a minimum value.
Contact the Service Department.
The operating voltage is too low.
Minimise the consumers,
check the battery,
check the cables,
check the alternator.
The operating voltage is too
high.
Check the alternator
The filling level sensor is no
longer covered with seed.
Replenish seed.
Calibration value is too high.
Repeat the calibration.
The travelled distance during
calibration was too short.
Repeat the calibration.
The travel speed is too high.
Compare the set speed with the
actual speed travelled.
Reduce the travel speed.