![Amazone Catros 4003-2TS Original Operating Manual Download Page 89](http://html1.mh-extra.com/html/amazone/catros-4003-2ts/catros-4003-2ts_original-operating-manual_2919720089.webp)
5.
Check that all of the disc carriers are aligned
evenly.
6.
Tighten the lock nuts.
CMS-I-00003385
10.1.5 Checking the rollers
INTERVAL
After initial operation
Every 200 operating hours
or
Every 3 months
Check the bolts
1
for tightness.
If the bolts need to be replaced,
pay attention to the alignment of the bolts.
Check the roller bearing
2
for ease of
movement.
2
2
1
1
CMS-I-00000099
10.1.6 Checking the lower link pins
INTERVAL
Every 500 operating hours
or
Every 6 months
1.
Check the lower link pins for cracks or broken
areas.
2.
Replace the pins if there is significant wear.
CMS-T-00002329-B.1
CMS-T-00004233-A.1
10 | Repairing the machine
Maintaining the machine
MG6828-EN-II | N.1 | 13.08.2021
83