Appliance Preparation

5. Remove the two packaged bulbs from inside    

  the HEPA filter.

6. Remove bulbs from packaging and screw into 

  sockets (Figure 3) attached to the cover.  

CAUTION:

  Do not use a tool to tighten the bulbs.  

Only tighten by hand.  Tighten bulbs by grasping the 

plastic base.  Do not grasp the glass tubes.

7. Carefully reposition the cover (Figure 4) over the 

  HEPA filter. Make sure cover is oriented as 

  previously installed and bulbs are not contacting 

  any surface.

8. Secure cover with retaining screw.  Connect 

  interconnect cord.  Device is now ready for 

 operation.

Operation

1. Unwrap the power cord and plug into the properly 

  grounded outlet.

2.  Make sure the interconnect cord is connected to the 

  receptacle on the base unit and the receptacle on 

  the cover above the fan.

3. Place the air mover in the desired operating position. 

4. Set the switch at the desired speed: low or high.

Circuit Protection

The 250AP features a circuit breaker that will “trip” if 

more than the rated electrical current is drawn through 

the cord.  In addition, some models are equipped with 

a duplex GFCI outlet. The GFCI protection promotes 

operator safety and will “trip” if an electrical ground fault 

is sensed. To test the GFCI protection, press the TEST 

button. If operating properly, the RESET button on the 

GFCI outlet will pop out. 

Figure 3

Figure 4

Summary of Contents for Pioneer Eclipse PE250AP

Page 1: ...Commercial Air Purifier PE250AP Operator s Manual...

Page 2: ...ng Law to cause cancer birth defects or other reproductive harm In certain locations including the State of California purchasers of these Products that place them in service at an employment job site...

Page 3: ...tements are ignored Read and observe all WARNING statements included in the Operation Manual and attached to the machine CAUTION indicates that the possibility of damage to the machine or other proper...

Page 4: ...expose to rain Do not use with damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water return it to an authorized service center Saf...

Page 5: ...n cause severe burns of the skin and eye injuries photokeratitis WARNING This device uses UV C bulbs or lamps that contain Mercury The U S Environmental Association EPA classifies Mercury as hazardous...

Page 6: ...POWER SWITCH HEPA FILTER PRE FILTER UV C BULB LIGHT FILTER Appliance Components Appliance Preparation Unpacking the Appliance When the appliance is delivered carefully inspect the shipping carton and...

Page 7: ...tion Operation 1 Unwrap the power cord and plug into the properly grounded outlet 2 Make sure the interconnect cord is connected to the receptacle on the base unit and the receptacle on the cover abov...

Page 8: ...interconnect cord Device is now ready for operation HEPA Replacement WARNING UV C emitted from this device CAUTION Do not operate device without filter and cover securely attached 1 Follow all safety...

Page 9: ...disposed as trash or rubbish They must be recycled For more information see the following US http www lamprecycle org Canada https www canada ca en environment climate change campaigns diverting mercu...

Page 10: ...10 Wiring Diagram...

Page 11: ...ilding circuit breaker Check the circuit breaker on the base Check the GFCI Bad connection Check the cord connection at the wall outlet Check the interconnect cord between the base and the filter cove...

Page 12: ...12 UpperAssembly RF083900 060921 22 1 15 1 14 1 11 3 6 1 17 4 23 1 21 1 8 1 16 4 19 3 10 2 18 4 5 2 13 1 2 1 7 1 9 1 28 1 24 1 20 1 4 1 3 1 1 1...

Page 13: ...X 3 8 PAN HD 3 13 MP542300 PRE FILTER HEPA 18 O D 1 14 85333A 1 4 20 x 2 PAN PHIL M S 1 15 IN1015 TRIM BATTERY TRAY 4 625 FT 1 16 NB031500 WASHER 5 16 BONDED NEOPRENE 4 17 NB073900 SCREW 8 32 X 1 RH...

Page 14: ...14 Lower Assembly 1 2 2 3 3 3 3 4 5 6 7 8 9 10 11 12 16 20 21 22 23 24 25 27 26 17 18 19 15...

Page 15: ...P 4 Pole MP541900 1 12 X8209S Screw 1 4 20 x 1 2 Self Locking Flange 1 15 X9187 GFCI Outlet Female 1 X2400 IEC plug 230V MP541900 1 16 X9190 Label Product 1 17 72721A Switch Panel 1 72721C Panel Switc...

Page 16: ...per hour for the first year of ownership 3 Parts repaired or replaced under this warranty are warranted only during the balance of the original warranty period All defective parts replaced under thes...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...er Eclipse Corporation 1 Eclipse Rd l PO Box 909 Sparta North Carolina 28675 l USA www pioneereclipse com 1 336 372 8080 1 800 367 3550 Fax 1 336 372 2913 2021 Amano Pioneer Eclipse Corporation LT0863...

Reviews: