DANGER:

•  To reduce the risk of fire, electric shocks or injury, please read and follow the safety instructions and 

warning indications before using. This vacuum cleaner has been designed to be safe when it is used for 

cleaning in the specified manner. If damage to electrical or mechanical components is found, the vacuum 

cleaner and/or the accessory must be repaired at the relative authorised service centre or else at the 

manufacturer before use, in order to prevent further damage to the machine or physical injury to the user.

•  Before connecting the machine to the electricity socket, make sure the electrical information on the plate 

corresponds to that of the mains supply. 

The machine must only be powered with alternating current 

and voltage equal to that shown on the serial number plate

.

•  The power supply cable outlet must have an earth connection in compliance with the regulatory standards.

•  Before using, check for any damage on the connection cable and on the power plug. If the cable is 

damaged, immediately contact a specialist technician for restoring normal operations.

•  Connect the machine only to an electrical connection installed by an electrical installer in conformity with 

IEC 60364-1.

•  Never touch the power plug with wet hands.

•  Make sure that the cable to the mains or the extension cable have not been damaged by having been 

walked on, crushed, pulled or the like. Protect the cable from heat and from contact with oils or sharp 

edges.

•  Regularly check that the cable connecting to the mains is not damaged, for example with signs of ageing 

or cracks. If there is damage, the cable must be replaced by a specialist TMB srl technician or else by a 

technician with similar qualifications before using the machine again.

•  Protection against splashes of water and the mechanical strength need to be ensured also after any 

replacement of the joints of the power cable or the extension cable.

•  Do not clean the machine with a hose or a jet of high pressure water (risk of short-circuit or other electrical 

faults).

ATTENTION:

•  The procedure causes short-term reduction in voltage.

•  In unfavourable grid conditions the other machines could be damaged.

•  This damage could occur if the grid impedance is less than 0.15Ω.

CONNECTION TO THE ELECTRICITY GRID

DANGER:

•  Never use with a damaged cable or plug. When removing from an electrical socket, pull the plug and not 

the cable. Do not handle the plug or the vacuum cleaner with wet hands. Deactivate all the controls before 

connecting or disconnecting from the electrical socket.

•  Do not pull or transport the machine by the cable, do not use the cable as a handle, do not close a door on 

the cable, and do not pull the cable around edges or sharp corners. Do not pass the vacuum cleaner over 

the cable. Keep the cable away from hot surfaces.

•  Be careful when cleaning on stairs.

•  The machine must not be used or kept outdoors, in damp conditions or directly exposed to rain.

•  The storage temperature must be between -13°F and +131°F.

•  Conditions of use: ambient temperature between 32°F and 104°F with a relative humidity between 30 and 

95%. The vacuum cleaner has been developed only for dry cleaning and it should not be used or kept 

outdoors in moist conditions.

USE - EMPLOYMENT

Summary of Contents for American Sanders AVAC12-P

Page 1: ...AVAC12 P Operator s Manual...

Page 2: ...ENANCE 9 TROUBLESHOOTING 10 TECHNICAL DATA 10 DISPOSAL 10 NOTES 29 PARTS LIST 30 ELECTRICAL SCHEMATIC 30 MAIN ASSEMBLY 31 VACUUM MOTOR COVER ASSEMBLY 32 TANK ASSEMBLY 34 HOSE ASSEMBLY 35 ACCESSORIES 3...

Page 3: ...ains is not damaged for example with signs of ageing or cracks If there is damage the cable must be replaced by a specialist TMB srl technician or else by a technician with similar qualifications befo...

Page 4: ...used by children over 8 years of age and by people with limited physical sen sorial or mental or by people who have no experience or the required knowledge as long as they are supervised or after they...

Page 5: ...ll the current safety norms Observe the safety check as per local provisions for commercial machines TRANSPORT MAINTENANCE Never leave the machine unattended until it is switched off and disconnect th...

Page 6: ...als expressly recommended by the manufac turer as cable extensions contact an authorised retailer or else high quality models When using an extension respect its minimum cross section CABLE LENGTH CAB...

Page 7: ...y claimed INTRODUCTORY COMMENT Any type of equipment can only work properly and effectively if used correctly and kept in full working order by performing the maintenance operations described in the a...

Page 8: ...t the plug from the mains socket by directly pulling the plug and not the cable 3 Remove the vacuum head 5 using the handle on it before removing the head loosen the locking catches 7 on the side of t...

Page 9: ...particularly clogged or if it is damaged replace it 4 Clean the inside of the collection tank with a damp cloth 5 Put back the vacuum head 1 on top of the collection tank 3 remembering to secure it wi...

Page 10: ...ry being used Connect the extension tube correctly to the vacuum accessory being used The vacuum circuit is blocked vacuum hose extension hose vacuum accessory Remove the obstruction in the vacuum cir...

Page 11: ...NTRETIEN 18 R SOLUTION PANNES 19 DONN ES TECHNIQUES 19 LIMINATION 19 GARANTIE LIMIT E 38 Lire et observer ces avertissements li s la s curit avant la premi re utilisation de l appareil Conserver ces a...

Page 12: ...s V rifier r guli rement que le c ble de raccordement au r seau de distribution lectrique n est pas endommag par exemple par la formation de fissures ou des traces de vieillissement Si on d tecte des...

Page 13: ...l utiliser pour aspirer des liquides inflammables ou combustibles tels que l essence ou dans des zones o ceux ci peuvent tre pr sents Ne pas aspirer d l ments qui br lent ou fument tels que des cigar...

Page 14: ...ETIEN Toujours utiliser l appareil pour l usage pr vu en tenant compte des conditions locales et en prenant garde l ventuelle pr sence de tiers notamment d enfants lors du travail Ne jamais laisser la...

Page 15: ...at riaux indiqu s clairement par le fabricant s adresser au distributeur agr ou des mod les sup rieurs en ce qui concerne la qualit Lors de l emploi d un c ble de rallonge observer la section minimale...

Page 16: ...ofit uniquement s il est utilis correctement et maintenu en pleine efficacit en effectuant l entretien d crit dans la documen tation en annexe Nous vous prions de bien vouloir lire ce manuel d utilisa...

Page 17: ...r le c ble 3 D poser la t te d aspiration 5 au moyen de la poign e situ e au dessus de celle ci avant de d poser la t te desserrer les crochets d arr t plac s c t du bidon de ramassage 6 fig 3 4 V rif...

Page 18: ...d aspiration 1 sur le bidon de ramassage 3 ne pas oublier de la fixer celui ci l aide des crochets d arr t 2 6 D brancher le tuyau d aspiration 7 de la buse d aspiration 8 du bidon de ramassage avant...

Page 19: ...is Brancher correctement le tuyau de rallonge l accessoire d aspiration utilis Il y a des impuret s qui bouchent le circuit d aspiration tuyau d aspiration tuyau de rallonge accessoire d aspiration En...

Page 20: ...sas ADVERTENCIAS DE SEGURIDAD PARA ASPIRADOR S LIDOS NIVELES DE PELIGRO ESPA OL NDICE 20 ADVERTENCIAS DE SEGURIDAD PARA ASPIRADOR S LIDOS 20 NIVELES DE PELIGRO 20 CONEXI N A LA RED EL CTRICA 21 USO EM...

Page 21: ...ado por ejemplo debido a la formaci n de grietas o envejecimiento Si el cable est da ado debe ser sustituido por un t cnico especializado de TMB SRL o por un t cnico que tenga una cualificaci n simil...

Page 22: ...n en zonas donde puede haber estos l quidos No recoger nada que se est quemando o despida humo como cigarros cerillas o cenizas incan descentes La m quina puede ser utilizada por ni os menores de 8 a...

Page 23: ...es para m quinas de uso comercial TRANSPORTE MANTENIMIENTO Utilice siempre el aparato de acuerdo con el uso previsto teniendo en cuenta las condiciones locales y prestando atenci n durante el trabajo...

Page 24: ...o cables de prolongaci n nicamente los materiales indicados expl citamente por el fabricante contactar con el revende dor autorizado o modelos de calidad superior Al utilizar un cable de prolongaci n...

Page 25: ...REVIA Todas las m quinas pueden funcionar bien y trabajar provechosamente tan solo con usarlas correctamente y manteniendo su plena eficiencia que se obtiene siguiendo el mantenimiento descrito en la...

Page 26: ...rando directamente de la clavija y no del cable 3 Aflojar los ganchos que sujetan el cabezal de aspiraci n ubicados al lado de la cuba de recogida 6 Fig 3 y desmontarlo 5 manipulando la manilla que se...

Page 27: ...cogida con un pa o h medo 5 Montar el cabezal de aspiraci n 1 sobre la cuba de recogida 3 y fijarlo a la misma cerrando los ganchos de retenci n 2 6 Desconectar el tubo de aspiraci n 7 de la boca de a...

Page 28: ...spiraci n que se est utilizando Conectar correctamente el tubo de alargue al accesorio de aspiraci n que se est utilizando Hay impurezas que obstruyen el circuito de aspiraci n tubo de aspiraci n tubo...

Page 29: ...___ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ ______...

Page 30: ...30 Electrical Schematic IG Double Pole Switch CO Capacitor MO Vacuum Motor...

Page 31: ...31 Main Assembly Item Ref No Description Qty 1 TMB227687 HEADBOARD 1 2 TMB228572 TANK GROUP AVAC 12 1 3 TMB228573 FLOAT GROUP 1 3 1 TMB444991 NYLON FILTER 1 3 2 TMB449319 FILTER BASKET 1...

Page 32: ...32 Vacuum Motor Cover Assembly...

Page 33: ...R BASE CL TOP 1 10 TMB445841 FILTER 1 11 TMB418117 1 12 TMB227838 1 13 TMB418340 HANDWHEEL 1 14 1 TMB444305 CABLE SJTW 3X14AWG 105D GREY PLUG USA 1 14 2 TMB417828 FAIRLEAD 1 15 TMB445369 WIRING HARNES...

Page 34: ...PORT ACCESSORIES 1 3 418017 CASTOR WHEEL 2 4 418287 SELF TAPPING SCREW 2 5 418140 STARLOOK D 20MM 2 6 408857 SCREW 2 7 416866 AXLE 1 8 417184 COVER 2 9 418012 WHEEL 2 10 409360 RIVET 4 11 449318 NOZZL...

Page 35: ...35 Hose Assembly Item Ref No Description Qty 1 TMB417735 HOSE 1 2 TMB400999 TUBE 1 3 TMB449357 MALE COUPLING 1...

Page 36: ...ACCESSORY STND 1 1 2 1 2 TMB225160 HOSE 1 1 2 25 FT 1 3 TMB401069 TUBE EXTENSION STEEL 1 4 TMB401072 TUBE EXTENSION PLASTIC 1 5 TMB431080 TOOL CREVICE 2 6 TMB442386 NOZZLE w BRISTLES 1 7 TMB442388 NO...

Page 37: ...ed only during the balance of the original warranty period All defective parts replaced under these warranties become the property of American Sanders WARRANTY SERVICE To obtain warranty service take...

Page 38: ...es d fectueuses remplac es en vertu de ces garanties deviennent la propri t d American Sanders SERVICE SOUS GARANTIE Pour obtenir du service sous garantie apportez votre appareil et une preuve d achat...

Page 39: ...a garant a original Todas las partes defectuosas reemplazadas bajo estas garant as se convierten en propiedad de American Sanders SERVICIOS DE GARANT A Para obtener servicio de garant a lleve su equip...

Page 40: ...s an AMANO Company 1 Eclipse Rd l PO Box 909 Sparta North Carolina 28675 l USA www pioneereclipse com www americansanders com 1 336 372 8080 1 800 367 3550 Fax 1 336 372 2913 2018 American Sanders LT0...

Reviews: