4

FAN SPEED (LOW, MED, HIGH) -  FAN
selects either a low, medium or high fan
speed to cool.

ENERGY SAVER  -  ENERGY SAVER mode
provides the most energy efficient use of your
room air conditioner.  This feature can be used

with SMART COOL or cooling with any fan speed.

Amana’s Temp-Asure

®

 air sampling system works to main-

tain the set temperature within 1.5°F while in ENERGY
SAVER mode.  Approximately every 5 minutes the fan will
come on and “sample” the room air to determine if cooling
is needed.  If the room is cool enough, the fan will cycle off.
If the room needs further cooling, the compressor  will
engage along with the fan until the set temperature is
reached.

ENERGY SAVER has a soft start fan feature.  This feature
starts the fan in low to reduce noise.

ACTION AIR -  ACTION AIR provides uni-
form cooling with a power sweeping action
to move the cooled air around the room.
This feature can be turned on and off by

pressing this button.

ARROW KEYS - These keys increase or
decrease the set temperature and clock
setting.

CLOCK  - The CLOCK button sets the
clock. The arrow keys adjust the time.  To
exit clock mode, press the clock button.
The time of day will be displayed.

Note:  Pressing this button twice quickly changes the
mode from time to temperature and vice-versa.  To briefly
display the time (if temperature is currently displayed) or
temperature (if time is currently displayed), press either the
up or down arrow key.

TIMER - The TIMER button is used to turn
the TIMER on and off as well as set the
TIMER.  The timer has four different timer

periods, P1, P2, P3, and P4.  Each period can be pro-
grammed with a different temperature setting  and opera-
tional mode. See page 5 for operation details.

Operation

Vent Control

Open or close the vent by sliding the vent control lever to
the appropriate setting.

EXHAUST - This setting opens the vent to move indoor air
out.

Note:  To conserve energy, the unit should be set to FAN
mode when using this setting.

CLOSED - In this position the vent is closed and room air
is recirculated and filtered.  This position should be used
for all normal cooling operations.

FRESH AIR - This setting opens the vent to move outside
air indoors.

Note: To conserve energy, the unit should be set to FAN
mode when using this setting.

Unit Control

OFF - Turns the unit off.  To turn the unit on,
press SMART COOL or MODE.

SMART COOL -   SMART COOL adjusts the
fan speed of the unit to achieve the selected
temperature.  The SMART COOL feature
uses computer logic to cool the room quickly

and quietly. Fan speeds start high, automatically switch to
medium and finally go to low as the room temperature
nears the set temperature.

MODE (COOL,DRY, FAN) -   MODE is
used to switch the operational mode of the
control between the COOL, FAN, and DRY
modes.  If the unit is off when this button is

pressed, the unit will come on with the last mode and
temperature setting.

MODE

COOL

DRY

FAN

ENERGY

SAVER

ACTION

AIR

CLOCK

TIMER

Control Panel

U LTR A  Q U IET ZO N E

EXHAUST     CLOSED      FRESH AIR

OFF

SMART

COOL

U LTR A  Q U IET Z O N E

EXHAUST     CLOSED     FRESH AIR

COOL

DRY

HIGH

FAN

MED

LOW

CLEAN FILTER

LOC KOUT

OFF

SMART

COOL

MODE

FAN

SPEED

ENERY

SAVER

ACTION

AIR

SET

CLOCK TIMER

SLEEP

LOW

HIGH

MED

FAN

SPEED

SET

Summary of Contents for Ultra Quiet Zone Room Air Conditioner

Page 1: ...propermaintenanceinformationformaxi mum benefit of the features selected Contents Electrical Requirements 3 Electrical Grounding Instructions 3 Safety Features 3 Compressor Lockout 3 Low Voltage Protection 3 Operation 4 Vent Control 4 Unit Control 4 Timer Operation 5 Special Features 6 Variable Differential Control VDC 6 Intellistat 6 Remote Control 7 Installing Batteries 7 Remote Control Operatio...

Page 2: ...be set from 60 F to 90 F in 1 increments Digital Temperature Time Display Shows either the time indoor room temperature in FAN ONLY mode or current temperature setting in other modes Automatic Recall Unit uses computer logic to recall settings when last turned on Variable Differential Control Vacation Mode Allows you to set limits on how far the temperature can vary from your settings Dry Mode Dry...

Page 3: ...n the line voltage reaches at least 100 VAC the control will reenergize your unit Note A compressor lockout will occur after the unit is reenergized Electrical Requirements Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for protection against possible shock hazards If a two prong wall receptacle is encountered the customer is required to contact a qu...

Page 4: ... the TIMER The timer has four different timer periods P1 P2 P3 and P4 Each period can be pro grammed with a different temperature setting and opera tional mode See page 5 for operation details Operation Vent Control Open or close the vent by sliding the vent control lever to the appropriate setting EXHAUST This setting opens the vent to move indoor air out Note To conserve energy the unit should b...

Page 5: ...Temperature Mode Energy Saver Action Air Period 1 6 00 AM 75 SMART COOL ON OFF Period 2 8 00 AM 80 SMART COOL ON OFF Period 3 4 00 PM 73 SMART COOL ON OFF Period 4 10 00 PM 77 SMART COOL ON OFF Default Timer Settings After five 5 seconds of no input the display will return to the time of day and the LED above the timer button will light This indicates the unit is operating in the programmed timer ...

Page 6: ...ential Control VDC This feature controls the temperature difference between when the unit turns off and restarts especially useful for extended periods outside the room Normally the unit will cycle on and off to maintain within 1 5 F of the temperature setting VDC enables the user to change this differential from 1 5 F to as much as 7 0 F To change the differential Be sure the unit is off Press an...

Page 7: ...e batteries to heat or flame Remote Control Operation You can operate your room air conditioner by remote control The only functions not available by remote control are activating and deactivating the LOCKOUT and reset ting of the CLEAN FILTER timer The SMART COOL ENERGY SAVER COOL DRY FAN ACTION AIR HIGH FAN MEDIUM and LOW FAN buttons operate the same as on the unit The POWER button turns the roo...

Page 8: ...should be inspected by an authorized servicer once a year to ensure proper function of the unit 1 Once a year remove chassis from outer case and thoroughly clean air conditioner 2 Wash air conditioner with warm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Do not use abrasive cleaners such as Comet Ajax etc These items can scra...

Page 9: ... is plugged in Check fuse or circuit breaker Control reset required Unplug unit and plug back in Compressor lockout on initial plug in Wait 3 minutes and recheck compressor Dirty air filter Clean air filter Air conditioner undersized for application Check with dealer to determine proper unit capacity for application Power interruption or changing switch settings from normal mode to energy saver or...

Page 10: ...y service is required If something is operating incorrectly read Before Calling for Service section Any Questions Most of your questions can be answered by your local Amana dealer Check with your dealer first if you need any further information regarding the operation maintenance or service of your unit Then if you should have any matters which are not resolved locally or if you would like informa...

Reviews: