background image

6

SLEEP - The SLEEP button starts a program
that adjusts the cooling comfort level.  The
program raises the cooling temperature 1°F

every hour for the next four hours.

LOCKOUT - LOCKOUT is a new child-
proof feature of the new Ultra Quiet Zone
room air conditioner.  This feature pre-

vents altering of the current settings on the unit.

To activate, press and hold for two sec-
onds the up and down arrow keys at the
same time.  When the LOCKOUT LED
lights up, the function is activated.  The
only command that is available during
lockout is the OFF button for deactiva-
tion.  To deactivate lockout, press the
arrow keys at the same time and hold until

the LOCKOUT LED goes off.

Note:  To turn off the display, press and hold the OFF and
CLOCK buttons at the same time until the display turns off.

CLEAN FILTER - After 250 hours of fan
runtime, the clean filter will flash.  This is
a reminder to remove and clean the filter.

To reset the counter and stop the flashing, press the OFF
button twice.

SLEEP

CLEAN FILTER

LOCKOUT

CLEAN FILTER

LOCKOUT

Special Features

Variable Differential Control (VDC)
This feature controls the temperature difference between
when the unit turns off and restarts especially useful for
extended periods outside the room.  Normally, the unit will
cycle on and off to maintain within 1.5°F of the temperature
setting.  VDC enables the user to change this differential
from 1.5°F to as much as 7.0°F.

To change the differential:

Be sure the unit is off.

Press and hold the OFF and FAN SPEED buttons.  When
the characters d#.## (“#.##” is the current value of the
differential) are displayed,  use the arrow keys and change
the differential.

Note:  The differential defaults to 1.5°F.  It changes in
increments of 0.5°F.  The maximum change is 7°F.

If the OFF and FAN SPEED buttons are released during the
setup, the VDC mode will be cancelled and the unit will shut
off.

Intellistat
This feature expands the use of normal delay timers by
using sophisticated adaptive computer logic.  The delay
timer is set using the clock.  Instead of turning on and off in
a preset number of hours, Intellistat works to be at the set
temperature at the set time.  For example, if you want the
room to be 72°F at 5:00 p.m., the Intellistat feature will start
the unit prior to 5:00 p.m. so that by 5:00 p.m. it will be at
your selected temperature.

(2 seconds)

SET

Summary of Contents for Ultra Quiet Zone Room Air Conditioner

Page 1: ...propermaintenanceinformationformaxi mum benefit of the features selected Contents Electrical Requirements 3 Electrical Grounding Instructions 3 Safety Features 3 Compressor Lockout 3 Low Voltage Protection 3 Operation 4 Vent Control 4 Unit Control 4 Timer Operation 5 Special Features 6 Variable Differential Control VDC 6 Intellistat 6 Remote Control 7 Installing Batteries 7 Remote Control Operatio...

Page 2: ...be set from 60 F to 90 F in 1 increments Digital Temperature Time Display Shows either the time indoor room temperature in FAN ONLY mode or current temperature setting in other modes Automatic Recall Unit uses computer logic to recall settings when last turned on Variable Differential Control Vacation Mode Allows you to set limits on how far the temperature can vary from your settings Dry Mode Dry...

Page 3: ...n the line voltage reaches at least 100 VAC the control will reenergize your unit Note A compressor lockout will occur after the unit is reenergized Electrical Requirements Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for protection against possible shock hazards If a two prong wall receptacle is encountered the customer is required to contact a qu...

Page 4: ... the TIMER The timer has four different timer periods P1 P2 P3 and P4 Each period can be pro grammed with a different temperature setting and opera tional mode See page 5 for operation details Operation Vent Control Open or close the vent by sliding the vent control lever to the appropriate setting EXHAUST This setting opens the vent to move indoor air out Note To conserve energy the unit should b...

Page 5: ...Temperature Mode Energy Saver Action Air Period 1 6 00 AM 75 SMART COOL ON OFF Period 2 8 00 AM 80 SMART COOL ON OFF Period 3 4 00 PM 73 SMART COOL ON OFF Period 4 10 00 PM 77 SMART COOL ON OFF Default Timer Settings After five 5 seconds of no input the display will return to the time of day and the LED above the timer button will light This indicates the unit is operating in the programmed timer ...

Page 6: ...ential Control VDC This feature controls the temperature difference between when the unit turns off and restarts especially useful for extended periods outside the room Normally the unit will cycle on and off to maintain within 1 5 F of the temperature setting VDC enables the user to change this differential from 1 5 F to as much as 7 0 F To change the differential Be sure the unit is off Press an...

Page 7: ...e batteries to heat or flame Remote Control Operation You can operate your room air conditioner by remote control The only functions not available by remote control are activating and deactivating the LOCKOUT and reset ting of the CLEAN FILTER timer The SMART COOL ENERGY SAVER COOL DRY FAN ACTION AIR HIGH FAN MEDIUM and LOW FAN buttons operate the same as on the unit The POWER button turns the roo...

Page 8: ...should be inspected by an authorized servicer once a year to ensure proper function of the unit 1 Once a year remove chassis from outer case and thoroughly clean air conditioner 2 Wash air conditioner with warm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Do not use abrasive cleaners such as Comet Ajax etc These items can scra...

Page 9: ... is plugged in Check fuse or circuit breaker Control reset required Unplug unit and plug back in Compressor lockout on initial plug in Wait 3 minutes and recheck compressor Dirty air filter Clean air filter Air conditioner undersized for application Check with dealer to determine proper unit capacity for application Power interruption or changing switch settings from normal mode to energy saver or...

Page 10: ...y service is required If something is operating incorrectly read Before Calling for Service section Any Questions Most of your questions can be answered by your local Amana dealer Check with your dealer first if you need any further information regarding the operation maintenance or service of your unit Then if you should have any matters which are not resolved locally or if you would like informa...

Reviews: