background image

9

Before Calling For Service

IMPORTANT NOTE: A dirty air filter reduces operating
efficiency.  Inspect filter at least once every week during
operation.  Wash permanent air filter with warm soapy
water.  Rinse the charcoal air filter with warm water only.  Do
not scrub!  Thoroughly dry before replacing.

Fan Motor
Fan motor is permanently lubricated so there is no need to
oil motor.

Slide out Chassis
Some models feature a slide out chassis for easier instal-
lation.  Refer to Installation Instructions provided with unit
for details on removing chassis from outer case.

CHARCOAL AIR FILTER

FILTER FRAME

Charcoal Air Filter Installation

Remove charcoal air filter from plastic bag.  Inset the three
tabs on the right side of the filter into the three slots on the
frame.  Carefully bow the middle of the filter until the two
tabs on the filter can be inserted into the two slots on the
filter frame.  Relax bow.

Difficulty

Possible Cause

Suggested Solution

Set fan control to position other than off.
Confirm power cord is plugged in.
Check fuse or circuit breaker.

Control reset required.

Unplug unit and plug back in.

Compressor lockout on initial plug-in.

Wait 3 minutes and recheck compressor.

Dirty air filter.

Clean air filter.

Air conditioner undersized for application.

Check with dealer to determine proper unit 
capacity for application.

Power interruption or changing switch settings 
from normal mode to energy saver or vice versa.

Let fan run. Compressor will automatically 
restart in approximately 3 minutes.

Loose parts.

Tighten any loose parts.

Weak building construction.

Provide additional support.

Water hitting fan blade.

Normal in high humidity.

Mounting support cannot be 
installed

Storm window frame has been installed into 
window.

Some models require the window sill to be 
adapted to accept the mounting support.  
Refer to Installation Instructions provided 
with the unit for details.

Odors in cooling

Mold, mildew or algae formation on wet surfaces

Place algaecide tablet in basepan.

Water in basepan

Water in basepan is picked up by the fan blade 
and thrown onto the warm outdoor coil where 
water then evaporates

Normal in high humidity.

Air conditioner will not operate

Little or no cooling

Noisy unit

No power to unit.

Summary of Contents for Ultra Quiet Zone Room Air Conditioner

Page 1: ...propermaintenanceinformationformaxi mum benefit of the features selected Contents Electrical Requirements 3 Electrical Grounding Instructions 3 Safety Features 3 Compressor Lockout 3 Low Voltage Protection 3 Operation 4 Vent Control 4 Unit Control 4 Timer Operation 5 Special Features 6 Variable Differential Control VDC 6 Intellistat 6 Remote Control 7 Installing Batteries 7 Remote Control Operatio...

Page 2: ...be set from 60 F to 90 F in 1 increments Digital Temperature Time Display Shows either the time indoor room temperature in FAN ONLY mode or current temperature setting in other modes Automatic Recall Unit uses computer logic to recall settings when last turned on Variable Differential Control Vacation Mode Allows you to set limits on how far the temperature can vary from your settings Dry Mode Dry...

Page 3: ...n the line voltage reaches at least 100 VAC the control will reenergize your unit Note A compressor lockout will occur after the unit is reenergized Electrical Requirements Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for protection against possible shock hazards If a two prong wall receptacle is encountered the customer is required to contact a qu...

Page 4: ... the TIMER The timer has four different timer periods P1 P2 P3 and P4 Each period can be pro grammed with a different temperature setting and opera tional mode See page 5 for operation details Operation Vent Control Open or close the vent by sliding the vent control lever to the appropriate setting EXHAUST This setting opens the vent to move indoor air out Note To conserve energy the unit should b...

Page 5: ...Temperature Mode Energy Saver Action Air Period 1 6 00 AM 75 SMART COOL ON OFF Period 2 8 00 AM 80 SMART COOL ON OFF Period 3 4 00 PM 73 SMART COOL ON OFF Period 4 10 00 PM 77 SMART COOL ON OFF Default Timer Settings After five 5 seconds of no input the display will return to the time of day and the LED above the timer button will light This indicates the unit is operating in the programmed timer ...

Page 6: ...ential Control VDC This feature controls the temperature difference between when the unit turns off and restarts especially useful for extended periods outside the room Normally the unit will cycle on and off to maintain within 1 5 F of the temperature setting VDC enables the user to change this differential from 1 5 F to as much as 7 0 F To change the differential Be sure the unit is off Press an...

Page 7: ...e batteries to heat or flame Remote Control Operation You can operate your room air conditioner by remote control The only functions not available by remote control are activating and deactivating the LOCKOUT and reset ting of the CLEAN FILTER timer The SMART COOL ENERGY SAVER COOL DRY FAN ACTION AIR HIGH FAN MEDIUM and LOW FAN buttons operate the same as on the unit The POWER button turns the roo...

Page 8: ...should be inspected by an authorized servicer once a year to ensure proper function of the unit 1 Once a year remove chassis from outer case and thoroughly clean air conditioner 2 Wash air conditioner with warm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Do not use abrasive cleaners such as Comet Ajax etc These items can scra...

Page 9: ... is plugged in Check fuse or circuit breaker Control reset required Unplug unit and plug back in Compressor lockout on initial plug in Wait 3 minutes and recheck compressor Dirty air filter Clean air filter Air conditioner undersized for application Check with dealer to determine proper unit capacity for application Power interruption or changing switch settings from normal mode to energy saver or...

Page 10: ...y service is required If something is operating incorrectly read Before Calling for Service section Any Questions Most of your questions can be answered by your local Amana dealer Check with your dealer first if you need any further information regarding the operation maintenance or service of your unit Then if you should have any matters which are not resolved locally or if you would like informa...