Grounding Instructions
WARNING
!
To avoid risk of electrical shock or death, this oven
must be grounded.
WARNING
!
To avoid risk of electrical shock or death, do not alter
the plug.
This oven MUST be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This
oven is equipped with a cord having a grounding wire with
a grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded.
Consult a qualified electrician or servicer if grounding
instructions are not completely understood, or if doubt
exists as to whether the oven is properly grounded.
Model
NEMA
Designation
Receptacle and
Plug
RFS10S
RFS12S
NEMA
5-20R/5-20P
120V-20AMP
Do not use an extension cord. If the product power
cord is too short, have a qualified electrician install a
three-slot receptacle. This oven should be plugged into
a separate 60 hertz circuit with the electrical rating as
shown in the appropriate drawing. When a microwave
oven is on a circuit with other equipment, an increase
in cooking times may be required and fuses can be
blown.