42
!"#$%!&'!()&*+,#!,(-&./,)"/0&1$)2&3"!!,&4$(506-7&8.&9&:8.&9&:.&9&4;<<= +&9&>?.<
COOK
PREHEAT
STANDBY
LEVEL
NOT
READY
COOK
PREHEAT
STANDBY
LEVEL
NOT
READY
COOK
PREHEAT
STANDBY
LEVEL
NOT
READY
1
2
3
1
3
5
7
9
To Enter Service Test Mode, oven door must be closed.
NOTE: Unit must be in OFF condition
or
INITIAL power up mode.
Press
Display
Toggles Magnetron 2
(Top Front) ON/OFF.
Timer counts up to 62 seconds and unit shuts off.
Timer counts up to 62 seconds and unit shuts off.
Component Evaluation
COOK
PREHEAT
STANDBY
LEVEL
NOT
READY
0 = Deactivated
1 = Activated
Displays actual Amperage,
will vary by model
Indicates
Service
Mode
If no Amperage, check for line
voltage at H.V. transformer
primary winding.
If no voltage, check:
Interlock switch (secondary)
Triac 3
H.V. board (relay K6 if 230 VAC,
K7 if 208 VAC, and triac 3
drive voltage T1 - G)
Wiring
If voltage is present, check:
H.V. components and wiring.
Then
NOTE: Pads will not beep when accessing Service Test Mode.
COOK
PREHEAT
STANDBY
LEVEL
NOT
READY
COOK
PREHEAT
STANDBY
LEVEL
NOT
READY
Toggles Magnetron 3
(Bottom) ON/OFF.
Toggles Magnetron 1
(Top Rear) ON/OFF.
Timer counts up to 62 seconds and unit shuts off.
If no Amperage, check for line
voltage at H.V. transformer
primary winding.
If no voltage, check:
Interlock switch (secondary)
Triac 1
H.V. board (relay K8 if 230 VAC,
K9 if 208 VAC, and triac 1
drive voltage T1 - G)
Wiring
If no Amperage, check for line
voltage at H.V. transformer
primary winding.
If no voltage, check:
Interlock switch (secondary)
Triac 2
H.V. board (relay K4 if 208 VAC,
K5 if 230 VAC, and triac 2
drive voltage T1 - G)
Wiring
To EXIT Service Test Mode press STOP/RESET pad.
High Voltage System # 1
High Voltage System # 2
High Voltage System # 3
Displays actual Amperage,
will vary by model
Displays actual Amperage,
will vary by model
NOTE:
Not Applicable on Two Magnetron models:
DQ22HSI, RC17S, RC17SD2, and RC22S.
If voltage is present, check:
H.V. components and wiring.
If voltage is present, check:
H.V. components and wiring.
MC units
DQ22HSI
MENU
WDYRC2
Hidden
Pad
RC units
MENU
1
2
3
4
BREAKFAST
REG MENU
PREP
MISC
Hidden
Pad
Hidden
Pad
Hidden
Pad
QUANTITY
Press Hidden Pad
as indicated above
on touch panels.
Summary of Contents for KFC2W2
Page 3: ...1 Important Safety Information 1 ...
Page 12: ...10 RC MRC 60 Hz Quick Start Reference Guide Sample 3 ...
Page 21: ...19 RC MRC 60 Hz Oven Construction 4 ...
Page 29: ...27 RC MRC 60 Hz Component Testing Procedures 7 ...
Page 41: ...39 RC MRC 60 Hz Service Test 8 ...
Page 47: ...45 RC MRC 60 Hz Wiring Diagrams Schematics 9 ...
Page 48: ...46 Wiring Diagram Sample Two Tube Models 9A BBCDBCB EF7 ...
Page 49: ...47 Schematic Sample Two Tube Models 9A BBCDBCB EF7 12719301 DANGER HIGH VOLTAGE ...
Page 50: ...48 Wiring Diagram Sample Two Tube Models 6 G 6 9A BBCDBCB EF7 Monitor Relay Board ...
Page 52: ...50 Wiring Diagram Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Page 53: ...51 Schematic Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Page 54: ...52 Wiring Diagram Sample Three Tube Models 9A BBCDBCB EF7 ...
Page 55: ...53 Schematic Sample Three Tube Models 9A BBCDBCB EF7 12719101 DANGER HIGH VOLTAGE ...
Page 56: ...54 Wiring Diagram Sample Three Tube Models 01 Monitor Relay Board ...
Page 57: ...55 Schematic Sample Three Tube Models 01 Monitor Relay Board ...
Page 58: ... 0 12 34 56 7 8 8 9 5 8 2 9 2 www acpsolutions com ...