28
Component Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
s
t
l
u
s
e
R
t
s
e
T
t
n
e
n
o
p
m
o
C
n
o
i
t
a
r
t
s
u
l
l
I
Thermal cutout
Disconnect all wires from TCO.
Measure resistance across terminals.
Magnetron TCO ....................................
Cavity TCO ........................................
Open at 300
°
F (149
°
C) and
closed at 257
°
F (125
°
C)
Opens at 262
°
F (128
°
C)
Diode
Discharge Capacitor
Remove diode lead from capacitor and
connect ohmmeter.
Reverse leads for second test.
Infinite resistance should be measured
in one direction and 50K
Ω
or more in
the opposite direction.
NOTE:
Ohmmeter must contain a
battery of 6 volts minimum.
MT2
MT1
GA TE
Triac
Resistance Check
Disconnect wires to triac.
Measure resistance from:
MT1 to MT2 ........................................
MT1 to Gate .......................................
MT2 to Gate .......................................
All terminals to ground ..........................
Caution - Do not operate oven with
wire to terminal MT2 removed.
Infinite
Approximately 60
Ω
Infinite
Infinite
Triac 1 (center)
Triac 2 (left)
Triac 3 (right
Voltage Check
Measure voltage from:
MT1 to Gate
0.8 VAC when energized. If no
voltage, check H.V. board and wiring.
Capacitor
Some units may use
more then one type of
capacitor. Refer to
Parts Manual for
correct capacitor
quantity.
Discharge Capacitor
Remove wires from capacitor terminals
and connect ohmmeter, set on highest
resistance scale to terminals.
Also check between each terminal and
capacitor case.
Between Terminals: Meter should
momentarily deflect towards zero then
return to over 5 M
Ω
. If no deflection
occurs, or if continuous deflection
occurs, replace capacitor.
Terminal to Case: Infinite resistance
Snubber assembly
Disconnect wires to snubber.
Measure resistance across terminals ........
Infinite
Magnetron
Discharge Capacitor
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and ground.
Between Terminals: Less than 1
Ω
Each terminal to ground measures
Infinite resistance.
Note:
This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
Blower motor
Remove all wires from motor.
Measure resistance between:
Orange and white terminals ......................
Yellow and white terminals ........................
Approximately 31
Ω
Approximately 29
Ω
!
WARNING
Blower motor
Remove all wires from motor.
Measure resistance across coil.............................
Approximately 25
Ω
(Prior to S/N 1107101263)
( Starting at
S/N 1107101263 and after)
Summary of Contents for KFC2W2
Page 3: ...1 Important Safety Information 1 ...
Page 12: ...10 RC MRC 60 Hz Quick Start Reference Guide Sample 3 ...
Page 21: ...19 RC MRC 60 Hz Oven Construction 4 ...
Page 29: ...27 RC MRC 60 Hz Component Testing Procedures 7 ...
Page 41: ...39 RC MRC 60 Hz Service Test 8 ...
Page 47: ...45 RC MRC 60 Hz Wiring Diagrams Schematics 9 ...
Page 48: ...46 Wiring Diagram Sample Two Tube Models 9A BBCDBCB EF7 ...
Page 49: ...47 Schematic Sample Two Tube Models 9A BBCDBCB EF7 12719301 DANGER HIGH VOLTAGE ...
Page 50: ...48 Wiring Diagram Sample Two Tube Models 6 G 6 9A BBCDBCB EF7 Monitor Relay Board ...
Page 52: ...50 Wiring Diagram Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Page 53: ...51 Schematic Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Page 54: ...52 Wiring Diagram Sample Three Tube Models 9A BBCDBCB EF7 ...
Page 55: ...53 Schematic Sample Three Tube Models 9A BBCDBCB EF7 12719101 DANGER HIGH VOLTAGE ...
Page 56: ...54 Wiring Diagram Sample Three Tube Models 01 Monitor Relay Board ...
Page 57: ...55 Schematic Sample Three Tube Models 01 Monitor Relay Board ...
Page 58: ... 0 12 34 56 7 8 8 9 5 8 2 9 2 www acpsolutions com ...