26
All Amana and Menumaster microwave oven power outputs are rated using the IEC705
standards. Using the IEC705 test method requires precision measurements and equipment that
is not practical to be performed in the field. Using the test shown below will indicate if the oven
performance is satisfactory.
Test equipment required:
1000 ml test container and thermometer (ACP Power Test Bowl part # 12018801).
Digital watch / watch with a second hand for use on ovens with electromechanical timers.
Important Notes:
Low line voltage will cause low temperature rise / power output.
Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same
circuit may cause a low temperature rise / power output.
This test and results are not a true IEC705 test procedures and are only intended to provide servicers with
an easy means of determining if the microwave oven cooking output is correct.
Procedure
1. Fill the test container to the 1000 ml line with cool tap water.
NOTE:
Water temperature should be approximately 60
!
F / 16
!
C
2.
Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1).
3. Place test container of water in the center of oven cavity and close door.
5. Heat the water for a 33-second full power cycle.
NOTE:
Use a digital watch or a watch with a second hand for ovens with electromechanical timers.
6. At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record
temperature (T2).
7. Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature
rise ( T).
8. If the temperature rise ( T) meets or exceeds the minimum, the test is complete. If the temperature rise ( T)
fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1-6
making sure to change the water. If the temperature rise ( T) fails to meet the minimum temperature rise again
the oven will require service.
Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time
T
Cooking
T
Cooking
T
Cooking
T
Cooking
(°F)
Power Output
(°F)
Power Output
(°C)
Power Output
(°C)
Power Output
10..................1000
20 .................2000
5 ...............1000
11 ............2000
11..................1100
21 .................2100
5.5 .............1100
11.5 .........2100
12..................1200
22 .................2200
6.5 .............1200
12 ............2200
14..................1400
24 .................2400
7.5 .............1400
13 ............2400
17..................1700
25 .................2500
9.5 .............1700
13.5 .........2500
18..................1800
27 .................2700
10 ..............1800
15 ............2700
19..................1900
30 .................3000
10.5 ...........1900
16.5 .........3000
NOTE:
Oven cavity must be cold.
4.
Place oven in to service mode and select service test pad 3. Magnetron will operate only.
Oven Performance Test
Summary of Contents for KFC2W2
Page 3: ...1 Important Safety Information 1 ...
Page 12: ...10 RC MRC 60 Hz Quick Start Reference Guide Sample 3 ...
Page 21: ...19 RC MRC 60 Hz Oven Construction 4 ...
Page 29: ...27 RC MRC 60 Hz Component Testing Procedures 7 ...
Page 41: ...39 RC MRC 60 Hz Service Test 8 ...
Page 47: ...45 RC MRC 60 Hz Wiring Diagrams Schematics 9 ...
Page 48: ...46 Wiring Diagram Sample Two Tube Models 9A BBCDBCB EF7 ...
Page 49: ...47 Schematic Sample Two Tube Models 9A BBCDBCB EF7 12719301 DANGER HIGH VOLTAGE ...
Page 50: ...48 Wiring Diagram Sample Two Tube Models 6 G 6 9A BBCDBCB EF7 Monitor Relay Board ...
Page 52: ...50 Wiring Diagram Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Page 53: ...51 Schematic Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Page 54: ...52 Wiring Diagram Sample Three Tube Models 9A BBCDBCB EF7 ...
Page 55: ...53 Schematic Sample Three Tube Models 9A BBCDBCB EF7 12719101 DANGER HIGH VOLTAGE ...
Page 56: ...54 Wiring Diagram Sample Three Tube Models 01 Monitor Relay Board ...
Page 57: ...55 Schematic Sample Three Tube Models 01 Monitor Relay Board ...
Page 58: ... 0 12 34 56 7 8 8 9 5 8 2 9 2 www acpsolutions com ...