WIRING DIAGRAMS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HI
G
H V
O
LT
A
G
E!
DI
SCO
NNE
CT
AL
L
PO
W
ER BE
FO
RE
S
ERV
ICI
NG
O
R I
NS
TA
LL
IN
G
T
HI
S
U
N
IT
. M
U
LT
IPL
E PO
W
ER
SO
U
R
C
ES M
AY B
E P
R
ESEN
T.
F
A
IL
U
R
E
TO
DO
S
O
M
AY
CAUS
E P
RO
PE
RT
Y DAM
AG
E,
P
ERS
O
NAL
INJ
UR
Y O
R DE
AT
H
.
106
ADPF, ARPF, ARUF, ATUF
USE COPPE R WIRE
SPEEDUP
COPP ER POWER SUP PLY
(SEE RATI NG PLAT E)
EQUIPMENT GROUND
BL
BL
SEE
NOT E 3
BK
M1
BR
BR
RC
EM
RD
BL
BK
RD
PU
WH
EBTDR
SR
BL
G
RD
XFMR-R
XFMR-C
C
R
RD
GR
SEE NOTE S 2 & 6
BL RD GR WH BR
5
NO
COM
NC
K1
K1
PU
PU
RD
RD
C
BK
BR
PLF
BK
1
RD
PU
2
3
240
24V
4
1
2
3
TR
RD
SEE
NOT E 4
BL
BR
4
5
WH
6
7
8
9
PLM
GRND
1
BK
2
3
RD
L2
L1
4
5
6
7
8
9
0140A00245-A
PLM
PLF
TR
FACTO RY WIRING
FIELDWIRING
NOTE S:
DELAY RELAY
STRAIN RELIEF
EVAPORATOR M OTOR
ELECTRONICBLOWER TIME
RUN CAPACITOR
SR
EM
EBTDR
RC
BK
RD
BL
YL
BLUE
BLACK
RED
YELLOW
COMPONENT CODE
BROWN
PURPLE
GREEN
PU
BR
GR
FEMALE PLU G CONNECTOR
MALE PLUG CONNECTOR
TRANSFORMER
HIGHVOLTAGE
LOW VOLTA GE
HIGHVOLTAGE
LOW VOLTA GE
PLF
3
2
COLOR CO DE
RD
TR
WH
6
BR
5
PLF
4
4
24V
5
SEE NOTE 1
1
2
3
RC
HI
EM
GR
WIRING CODE
BL
EBTDR
LO
COM
NC
M1
EBTDR
NO
208/240 VOLTS
1
1
PLF
PLM
L1
PLM
2
L2
(M2)
PU
RC
(M1) BK
BL
MEDIUM
3 SPEED
BR
HIGH
EM
(COM) RD
LOW
IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY
USE WIRE THAT CONFORMS TO THE
NATIONAL ELECTRIC CODE.
M2
PU
(TR 1)
M2
R
G
C
EBTDR
SEE NOTE 1
FL
FUSE LI NK
TL
THERMA L LIMIT
SEE NOTE 5
R
RELAY
TERMINA L BLOCK SHOW N
FOR 50HZ MODELS ONLY
THREE SP EED MO TOR WIRING
(SELEC T MOD ELS ONLY)
SEE NOTE 3
WHITE
WH
USE MIN . 75˚C FIELD WIRE
1. RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND
ONTERMINAL "2" FOR 208 VOLTS
2. SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER
LOW VOLTAGE WIRING CONNECTIONS
3. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP
NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTORWIRE (RED FOR LOW,
BLUE FOR MEDIUM, AND BLACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR
INACTIVE MOTORWIRES MUST BE CONNECTED TO "M1 OR M2"ON EBTDR.
4. BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY.
5. EBTDR HAS A 7 SECOND ON DELAY WHEN "G" IS ENERGIZED AND A 65 SECOND OFF
DELAY WHEN "G" IS DE-ENERGIZED.
6. LOW VOLTAGE FIELD WIRING TO BEN.E.C CLASS 2 WIRES.
GRND
GROUND