background image

SS-AMVC8

 

www.amana-hac.com 

7

www.amana-hac.com 

SS-AMVC8

p

roDuCT

 S

peCiFiCATionS

p

roDuCT

 S

peCiFiCATionS

AMVC8 A

irFlow

 D

ATA

 (

ConT

.)

H

eATing

 S

peeDS

 

AMVC80604B** 

(Rise Range: 20° - 50°F)

AMVC80805C** 

(Rise Range: 20° - 50°F)

Cooling 

Speed Tap

Adjust 

Tap

Low-Stage 

CFM¹

High-Stage 

CFM¹

Rise 

(°F)

Cooling 

Speed Tap

Adjust 

Tap

Low-Stage 

CFM¹

High-Stage 

CFM¹

Rise 

(°F)

A

Minus (-)

790

1125

46

A

Minus (-)

945

1350

49

Normal

875

1250

41

Normal

1050

1500

44

Plus (+)

960

1375

38

Plus (+)

1155

1650

40

B

Minus (-)

850

1215

43

B

Minus (-)

1010

1440

46

Normal

945

1350

38

Normal

1120

1600

42

Plus (+)

1040

1485

35

Plus (+)

1230

1760

38

C

Minus (-)

915

1305

40

C

Minus (-)

1070

1530

44

Normal

1015

1450

36

Normal

1190

1700

39

Plus (+)

1115

1595

33

Plus (+)

1310

1870

36

D

Minus (-)

975

1395

37

D

Minus (-)

1135

1620

41

Normal

1085

1550

33

Normal

1260

1800

37

Plus (+)

1195

1705

30

Plus (+)

1385

1980

34

AMVC81005C** 

(Rise Range: 25° - 55°F)

Cooling 

Speed Tap

Adjust 

Tap

Low-Stage 

CFM¹

High-Stage 

CFM¹

Rise 

(°F)

A

Minus (-)

1090

1555

55

Normal

1210

1725

49

Plus (+)

1330

1900

45

B

Minus (-)

1105

1575

54

Normal

1225

1750

49

Plus (+)

1350

1925

44

C

Minus (-)

1120

1600

53

Normal

1245

1775

48

Plus (+)

1370

1955

44

D

Minus (-)

1135

1620

53

Normal

1260

1800

47

Plus (+)

1385

1980

43

Notes

•  These charts are for furnaces installed at 0’ - 4,500’. At higher alti-

tudes, a properly de-rated unit will have the same temperature rise 
at a particular CFM, while the ESP at that CFM will be lower.

•  The installation must be adjusted to obtain a temperature rise 

within the range listed on the furnace nameplate.

•  Do not operate above .5” w.c. ESP in heating mode.
•  Propane gas installations will have a high-stage rise approximately 

4°F lower than shown in the tables.

C

onTinouS

 F

An

 S

peeDS

 

Model

Furnace 

Maximum CFM

Continuous 

Fan Speed¹

,

²

AMVC80604B**

1760

440

AMVC80805C**

2000

500

AMVC81005C**

2000

500

¹    Continuous fan speed is 25% of furnace maximum CFM
²    Three continuous fan speeds are possible with the CTK01AA thermo-

stat: 25%, 50%, and 75% of furnace maximum CFM

¹  @ .1” to .8” W.C. ESP

Summary of Contents for ADVC8 Series

Page 1: ...Low NOx emissions compliant models available Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Designed for multi position installation upflow horizontal left...

Page 2: ...H High Air ow K Dedicated Up ow Cabinet Width M Up ow Horizontal A 14 B 17 Descrip5on Motor C 21 V Two Stage Variable speed D 24 H Two Stage MulS speed S Single Stage MulS speed Maximum CFM 0 5 ESP E...

Page 3: ...No of Burners 3 4 5 3 4 5 Disposable Filter Size in 610 813 1 016 474 569 711 Electrical Data Min Circuit Ampacity 12 1 12 1 12 1 12 1 12 1 12 1 Max Overcurrent Device amps 15 15 15 15 15 15 Ship Weig...

Page 4: ...utlined in the Installation Manual for additional venting requirements Dimensions Model A B AMVC80604B 17 16 AMVC80805C 21 19 AMVC81005C 21 19 PRODUCT DIMENSIONS 8 AMVC8 GMVC8_____X Alt Gas Inlet High...

Page 5: ...Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined in the Installation Manual for additional venting requirements Auto Comfort Mode During Auto Comfort mode the fu...

Page 6: ...s 1 053 D Minus 1 053 Normal 910 Normal 1 170 Normal 1 170 Plus 1 001 Plus 1 287 Plus 1 287 1 to 8 W C ESP High or Single Stage Cooling Speeds AMVC80604B AMVC80805C AMVC81005C Cooling Speed Tap Adjust...

Page 7: ...High Stage CFM Rise F A Minus 1090 1555 55 Normal 1210 1725 49 Plus 1330 1900 45 B Minus 1105 1575 54 Normal 1225 1750 49 Plus 1350 1925 44 C Minus 1120 1600 53 Normal 1245 1775 48 Plus 1370 1955 44 D...

Page 8: ...Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM A Minus 351 A Minus 468 A Minus 497 Normal 390 Normal 520 Normal 553 Plus 429 Plus 572 Plus 608 B Min...

Page 9: ...age CFM High Stage CFM Rise F A Minus 975 1395 61 Normal 1085 1550 55 Notes These charts are for furnaces installed at 0 4 500 At higher alti tudes a properly de rated unit will have the same temperat...

Page 10: ...10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Page 11: ...ROLS IND LO 40 VA AUTO RESET AUXILIARY LIMIT CONTROLS YL JUNCTION BLWR PU PURPLE CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR...

Page 12: ...lity products may mean a change in specifications without notice 2012 Goodman Company L P Houston Texas Printed in the USA Accessories Model Description LPM 06 LP Conversion Kit Springs Orifice AFE18...

Reviews: