SS-AMVC8
www.amana-hac.com
3
2
www.amana-hac.com
SS-AMVC8
p
roDuCT
S
peCiFiCATionS
p
roDuCT
S
peCiFiCATionS
S
peCiFiCATionS
AMVC8
0604B*B
AMVC8
0805C*B
AMVC8
1005C*B
ADVC8
0603B*B
ADVC8
0805C*B
ADVC8
1005C*B
Heating Capacity
High Fire Input (BTU/h)¹
60,000
80,000
100,000
60,000
80,000
100,000
High Fire Output (BTU/h)¹ (below)
Natuarl Gas
48,000
64,000
80,000
48,000
64,000
80,000
LP Gas
48,000
64,000
80,000
48,000
64,000
80,000
Low Fire Input (BTU/h)¹
42,000
56,000
70,000
42,000
56,000
70,000
Low Fire Output (BTU/h)¹ (below)
Natuarl Gas
33,600
44,800
56,000
33,600
44,800
56,000
LP Gas
33,600
44,800
56,000
33,600
44,800
56,000
AFUE2
80
80
80
80
80
80
Available AC @ 0.5” ESP
1.5 - 4.0
2.0 - 5.0
2.0 - 5.0
1.5 - 3.0
2.0 - 5.0
2.0 - 5.0
Temperature Rise Range (° F)
20 - 50
20 - 50
25 - 55
30-60
35 - 65
35-65
Circulator Blower
Size (D x W)
10” x 8”
10” x 10”
10” x 10”
10” x 8”
10” x 10”
10” x 10”
Horsepower - RPM
¾
¾
¾
¾
¾
¾
Speed
Variable
Variable
Variable
Variable
Variable
Variable
Vent Diameter²
4”
4”
4”
4”
4”
4”
No. of Burners
3
4
5
3
4
5
Disposable Filter Size (in²)
610
813
1,016
474
569
711
Electrical Data
Min. Circuit Ampacity³
12.1
12.1
12.1
12.1
12.1
12.1
Max. Overcurrent Device (amps)⁴
15
15
15
15
15
15
Ship Weight (lbs)
152
178
194
155
177
193
1
Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is
75% of high-fire rate.
2
DOE AFUE based upon Isolated Combustion System (ICS)
3
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical
Codes. Extensive wire runs will require larger wire sizes.
4
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of
the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½” FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.