background image

SS-AMVC8

 

www.amana-hac.com 

9

www.amana-hac.com 

SS-AMVC8

p

roDuCT

 S

peCiFiCATionS

p

roDuCT

 S

peCiFiCATionS

ADVC8 A

irFlow

 D

ATA

H

igH

or

 S

ingle

-S

TAge

 C

ooling

 S

peeDS

ADVC80603B**

ADVC80805C**

ADVC81005C**

Cooling

Speed Tap

Adjust 

Tap

CFM¹

Cooling

Speed Tap

Adjust 

Tap

CFM¹

Cooling

Speed Tap

Adjust 

Tap

CFM¹

A

Minus (-)

540

A

Minus (-)

720

A

Minus (-)

765

Normal

600

Normal

800

Normal

850

Plus (+)

660

Plus (+)

880

Plus (+)

935

B

Minus (-)

720

B

Minus (-)

990

B

Minus (-)

1,035

Normal

800

Normal

1,100

Normal

1,150

Plus (+)

880

Plus (+)

1,210

Plus (+)

1,265

C

Minus (-)

900

C

Minus (-)

1,260

C

Minus (-)

1,305

Normal

1,000

Normal

1,400

Normal

1,450

Plus (+)

1,100

Plus (+)

1,540

Plus (+)

1,595

D

Minus (-)

1,080

D

Minus (-)

1,620

D

Minus (-)

1,665

Normal

1,200

Normal

1,800

Normal

1,850

Plus (+)

1,320

Plus (+)

1,980

Plus (+)

2000*

l

ow

-S

TAge

 C

ooling

 S

peeDS

 

ADVC80603B**

ADVC80805C**

ADVC81005C**

Cooling

Speed Tap

Adjust 

Tap

CFM¹

Cooling

Speed Tap

Adjust 

Tap

CFM¹

Cooling

Speed Tap

Adjust 

Tap

CFM¹

A

Minus (-)

351

A

Minus (-)

468

A

Minus (-)

497

Normal

390

Normal

520

Normal

553

Plus (+)

429

Plus (+)

572

Plus (+)

608

B

Minus (-)

468

B

Minus (-)

644

B

Minus (-)

673

Normal

520

Normal

715

Normal

748

Plus (+)

572

Plus (+)

787

Plus (+)

822

C

Minus (-)

585

C

Minus (-)

819

C

Minus (-)

848

Normal

650

Normal

910

Normal

943

Plus (+)

715

Plus (+)

1,001

Plus (+)

1,037

D

Minus (-)

702

D

Minus (-)

1,053

D

Minus (-)

1,082

Normal

780

Normal

1,170

Normal

1,203

Plus (+)

858

Plus (+)

1,287

Plus (+)

1,323

¹  @ .1” to .8” W.C. ESP

Notes

•  These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular 

CFM, while the ESP at that CFM will be lower.

•  THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.
•  Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.

Summary of Contents for ADVC8 Series

Page 1: ...Low NOx emissions compliant models available Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Designed for multi position installation upflow horizontal left...

Page 2: ...H High Air ow K Dedicated Up ow Cabinet Width M Up ow Horizontal A 14 B 17 Descrip5on Motor C 21 V Two Stage Variable speed D 24 H Two Stage MulS speed S Single Stage MulS speed Maximum CFM 0 5 ESP E...

Page 3: ...No of Burners 3 4 5 3 4 5 Disposable Filter Size in 610 813 1 016 474 569 711 Electrical Data Min Circuit Ampacity 12 1 12 1 12 1 12 1 12 1 12 1 Max Overcurrent Device amps 15 15 15 15 15 15 Ship Weig...

Page 4: ...utlined in the Installation Manual for additional venting requirements Dimensions Model A B AMVC80604B 17 16 AMVC80805C 21 19 AMVC81005C 21 19 PRODUCT DIMENSIONS 8 AMVC8 GMVC8_____X Alt Gas Inlet High...

Page 5: ...Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined in the Installation Manual for additional venting requirements Auto Comfort Mode During Auto Comfort mode the fu...

Page 6: ...s 1 053 D Minus 1 053 Normal 910 Normal 1 170 Normal 1 170 Plus 1 001 Plus 1 287 Plus 1 287 1 to 8 W C ESP High or Single Stage Cooling Speeds AMVC80604B AMVC80805C AMVC81005C Cooling Speed Tap Adjust...

Page 7: ...High Stage CFM Rise F A Minus 1090 1555 55 Normal 1210 1725 49 Plus 1330 1900 45 B Minus 1105 1575 54 Normal 1225 1750 49 Plus 1350 1925 44 C Minus 1120 1600 53 Normal 1245 1775 48 Plus 1370 1955 44 D...

Page 8: ...Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM A Minus 351 A Minus 468 A Minus 497 Normal 390 Normal 520 Normal 553 Plus 429 Plus 572 Plus 608 B Min...

Page 9: ...age CFM High Stage CFM Rise F A Minus 975 1395 61 Normal 1085 1550 55 Notes These charts are for furnaces installed at 0 4 500 At higher alti tudes a properly de rated unit will have the same temperat...

Page 10: ...10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Page 11: ...ROLS IND LO 40 VA AUTO RESET AUXILIARY LIMIT CONTROLS YL JUNCTION BLWR PU PURPLE CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR...

Page 12: ...lity products may mean a change in specifications without notice 2012 Goodman Company L P Houston Texas Printed in the USA Accessories Model Description LPM 06 LP Conversion Kit Springs Orifice AFE18...

Reviews: