RS5320016 Rev. 0
4
WARNING
!
To avoid risk of electrical shock, personal injury or
death; verify earthing instructions are followed.
Earthing Instructions
WARNING
!
Do not remove earthing prong when installing earthed
appliance in a home or business that does not have
three wire earthing receptacle, under no condition is
earthing prong to be cut off or removed. It is the
personal responsibility of the consumer to contact a
qualified electrician and have properly earthed three
prong wall receptacle installed in accordance with
appropriate electrical codes
Should a two prong adapter plug be required temporarily
it is the personal responsibility of the consumer to have it
replaced with properly earthed three prong receptacle or
the two prong adapter properly earthed by a qualified
electrician in accordance with appropriate electrical
codes.
Servicing of Earthed Products
The standard accepted color coding for earthing wires is
GREEN or GREEN WITH YELLOW STRIPE. These
earth leads are NOT to be used as current carrying
conductors. It is extremely important that the technician
replace any and all earths prior to completion of the
service call. Under no condition should earth wire be left
off causing a potential hazard to technicians and
consumer.
WARNING
!
Precautions to be observed before and during
servicing to avoid possible exposure to excessive
microwave energy, or electrical shock disconnect
power to oven.
Do not operate or allow oven to be operated with door
open.
Make the following safety checks on all ovens to be
serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
• Interlock operation
• Proper door closing
• Seal and sealing surfaces (arcing, wear, and other
damage)
• Damage to or loosening of hinges and latches
• Evidence of dropping or abuse
Before turning on microwave power for any service test
or inspection within the microwave generating
compartments, check the magnetron, waveguide or
transmission line, and cavity for proper alignment,
integrity, and connections.
Any failed or misadjusted components in the
interlock, monitor, door seal, and microwave
generation and transmission systems shall be
repaired, replaced or adjusted by procedures
described in this manual before oven is released to
the consumer.
Check microwave leakage to verify compliance with
the federal performance standard should be performed
on each oven prior to release to the consumer.
WIRING
Good service practice is to never route wiring over
terminals and/or sharp edges. This applies to any wiring
without regard to the circuit voltage. Wire insulation
material and thickness is designed and regulated for
electrical spacing purpose only, but cannot always be
relied upon because of possible cuts and/or abrasions,
which can occur during servicing.
Important Product Information