Trouble Shooting
ICE & WATER
TOPIC
POSSIBLE CAUSE
SOLUTION
Ice maker is not producing
ice (some models-continued)
Improper water valve was installed.
Check water connection procedure in your
Installation
Instructions
. Self-piercing and
3
/
16
” saddle valves cause low
water pressure and may clog the line over time.
Amana is not
responsible for property damage due to improper
installation or water connection.
Plastic tubing was used to complete water
connection.
Amana recommends using copper tubing for installation.
Plastic is less durable and can cause leakage.
Amana is
not responsible for property damage due to improper
installation or water connection.
Unit is leaking water
Improper water valve was installed.
Check water connection procedure in your
Installation
Instructions
. Self-piercing and
3
/
16
” saddle valves cause low
water pressure and may clog the line over time.
Amana is
not responsible for property damage due to improper
installation or water connection.
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
square inch to function properly. A minimum pressure of 35
pounds per square inch is recommended for units with
water filters.
Ice forms in inlet tube to ice
maker
Freezer temperature is too high.
See the controls section in your owner’s manual for
assistance on how to adjust your controls. Freezer is
recommended to be between 0 to 2°F (-18 to –17°C).
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
square inch to function properly. A minimum pressure of 35
pounds per square inch is recommended for units with
water filters.
Improper water valve was installed.
Check water connection procedure in your
Installation
Instructions
. Self-piercing and
3
/
16
” saddle valves cause low
water pressure and and may clog the line over time.
Amana is not responsible for property damage due to
improper installation or water connection.
Copper or plastic tubing has kinks.
Turn off water supply and remove kinks. If kinks cannot be
removed, replace tubing.
Water flow is slower than
normal
Water filter is clogged or needs to be
changed.
Change water filter.
Refrigerator has been recently installed
Water supply in holding tank has been
depleted.
Allow approximately 12 hours for water in holding tank to
chill.
Dispenser water is not cold
Water has settle into water lines outside
holding tank and has warmed to room
temperature.
Discard first glass of water and refill.