SPEd
Unit
Units to be used for
NMEA
mode
MS
,
MPH
,
hPH
or
hnot
MS
/
dFLt
dISP
Default display for
NMEA
mode
dir
,
SPEd
or
SCAN
SCAN
/
SCAN
SECS
Number of seconds between scans
0
to
255
0
/
CodE
Data type for display
dISP
,
ASCI
,
UAL
,
ARtH
,
M.buS
,
PtA
,
SCAN
,
NMEA
or
CS
dISP
??
/
??
A1
OPER
Alarm relay 1 operation mode
INPt
,
t.out
or
both
INPt
/
A2
OPER
Alarm relay 2 operation mode
INPt
,
t.out
or
both
INPt
/
dS.to
Display timeout
0
to
9999
10
/
t.out
Data string timeout
0.0
to
10.0
1.0
/
P.but
P
button function
NONE, Hi, Lo,
HILo, tARE
or
ZERO
NONE
/
R.INP
Remote input (external input) one
function
NONE, P.HLd,
d.HLd, Hi, Lo
, HiLo, tARE,
ZERO, SP.Ac,
No.Ac
or
duLL
NONE
/
ACCS
Access mode
OFF, EASY,
NONE
or
ALL
OFF
/
SPAC
Setpoint access mode (
∗
Optional
)
A1, A1-2
etc.
A1
/
A1
Alarm relay 1 operation channel
ch0
to
ch8
ch0
/
A2
Alarm relay 2 operation channel
ch0
to
ch8
ch0
/
bAUd
RAtE
Baud rate for serial
communications
300, 600,
1200, 2400,
4800, 9600,
19.2
or
38.4
9600
/
PrtY
Parity for serial input
NONE, EUEN
or
Odd
NONE
/
dAtA
Data type
8.bit
or
7.bit
8.bit
/
SER.1
tYPE
Serial communications type
(
∗
Optional
)
NONE, R232
or
R485
NONE
/
SER.2
tYPE
Not applicable to this model
NONE, R232
or
R485
NONE
/
(
∗
Optional
)—this function will only be accessible if the relevant option is fitted
42 of
LDRSMANADD-2.3-0