HiLo
- toggle between
Hi
and
Lo
displays. This function allows the remote input to be used to toggle
between peak and valley memory displays. The first operation of the remote input will cause the
peak memory value to be displayed, the next operation will give a valley memory display.
P Hi
or
P Lo
will flash before each display to give an indication of display type.
tARE
- display tare. Short circuiting the remote input pins momentarily will allow toggling between
nett and gross values (shown as
NEtt
and
GROS
). If the remote input is short circuited for approx.
2 seconds the display will be tared and will show zero. The tare will be lost if power is removed.
ZERO
- display zero. Zeroes the display in same manner as the tare function except that the zero is
not lost when power is removed and the display will zero as soon as the remote input is shorted.
When the
ZERO
operation is used the gross value cannot be recalled and the input at the time of
the
ZERO
operation will become the new zero point.
SP.Ac
- setpoint access only. This blocks access to any functions except the alarm setpoint functions
unless the remote input pins are short circuited or entry is made via
CAL
mode or if the
ACCS
function is set to
ALL
.
No.Ac
- no access. This blocks access to all functions unless the remote input pins are short circuited
or entry is made via
CAL
mode or if the
ACCS
function is set to
ALL
.
duLL
- display brightness control. The remote input can be used to change the display brightness.
When this mode is selected the display brightness can be switched, via the remote input terminals,
between the brightness level set at the
brGt
function and the brightness level set at the
duLL
function.
4.91
Alarm relay 1 operation channel
Display:
A1
Range:
ch0
to
ch8
Default Value:
ch0
Alarm relay 1 allocation - applicable only to
Arth
,
NMEA
,
SCAN
and
CS
modes. Allows relay 1 to be
allocated to one channel. Settings available are
ch0
,
ch1
,
ch2
,
ch3
,
ch4
,
ch5
,
ch6
,
ch7
or
ch8
.
In
NMEA
mode
ch1
represents wind direction and
ch2
represents wind speed. In
Arth
mode
ch0
represents the arithmetic result.
ch0
should not be selected for any other mode.
4.92
Alarm relay 2 operation channel
Display:
A2
Range:
ch0
to
ch8
Default Value:
ch0
Alarm relay 2 allocation - applicable only to
Arth
,
NMEA
,
SCAN
and
CS
modes. Allows relay 2 to be
allocated to one channel. Settings available are
ch0
,
ch1
,
ch2
,
ch3
,
ch4
,
ch5
,
ch6
,
ch7
or
ch8
.
In
NMEA
mode
ch1
represents wind direction and
ch2
represents wind speed. In
Arth
mode
ch0
represents the arithmetic result.
ch0
should not be selected for any other mode.
4.93
Clear zero
Display:
CLr ZERO
Range:
n/a
Default Value:
n/a
Seen only when
Code
function =
UAL
or
ARtH
. Allows any zero operations performed via the remote
input or
P
button to be cleared. Pressing the
^
and
v
buttons simultaneously will clear the zero offset,
the message
CLrd
will be seen, confirming the zero clearing operation is completed. The instrument will
then return to displaying the value of the string sent.