26
Monta
ż
baterii
1. Odłączsystemwodociągowy(ciepłąizimną wodę). Wkręć złączki mimośrodowedo wy-
lotów rurociągów, wstępnie uszczelniając cześć gwintową materiałem izolacyjnym. Wybierz
takie położenie złączek mimośrodowych, żeby pasowały do siebie i odpowiadały położeniu
montażowemu baterii. Położenie baterii powinno być poziome, odległość pomiędzy środ-
kami mimośrodów – 150 mm.
150mm
Spirit Level
37-44
mm
7
2. Remove (screw loose) aerator of bath/
shower mixer (to avoid aerator clogging
during first water startup).
3. Install wall plates onto the eccentric
adaptors using a tool with soft coating (to
avoid damage of mixer nuts decorative
cover), connect mixer housing.
Maintenance recommendations:
General recommendations:
To avoid lime spots at the mixer housing the mixer is recommended to be regularly
cleaned. Mixer cleaning should be carried out by soap solution with the following rinse
with water and removing moisture by dry soft cloth.
Remains of liquid soap, shampoo, shower gel may also cause damages of decorative cover.
In case of their penetration onto the mixer housing it should be thoroughly cleaned with
clean water
To avoid damages of product surface it is forbidden to use abrasive solutions and pastes-
for its cleaning.
To avoid changes color of decorative cover it is forbidden to use chemicals for cleaning
that contain aggressive chemical substances of acids, alkali, ammonium chloride and other
components containing chlorine.
Kitchen mixer/ Basin mixer/ Bidet mixer/ Bath/Shower mixer
Irregularity of the water sheet, its spray, appearance of noises the consequence of aerator
contamination. Regularcleaningof the aerator is recommended by means of its removal
and rinse with water. Aerator contamination risk and mixer cartridge breakage may be sig-
nificantly reduced by means of filters installation of 100-300 mk before mixer to the water
supply pipes that prevent penetration off foreign particles (rust, sand, etc.).
4. Switch on water supply system. Once
mixer is in the closed position check all
connections for leakproofness. When nec-
essary arrange additional tightening and
sealing of connections.
5. Connect shower hose and hand shower.
CLOTH
Summary of Contents for LIKE F8002100
Page 1: ...32 4 5 100 300 1 CLOTH LIKE...
Page 13: ...20 100 300 i 0 5 6 0 50 620 2 0 5 0 206 515 10 F8010000 F8020000 13 F8002100 F8093000 RUS...
Page 15: ...18 F8002100 F8093000 I i i i UA 15 100 300 0 5 6 0 50 620 2 0 5 0 206 515 10 F8010000 F8020000...
Page 16: ...16 1 150 150mm Spirit Level 37 44 mm 17 2 3 100 300 4 5 6 7 CLOTH...