background image

28

F8002100

F8093000

龙头安装说明书

面盆龙头、妇洗器龙头和厨房水槽龙头(
用于水平表面安装)

CN

5

Operating interval of pressure in water supply network 0,5 – 6,0 Atm.(50-620kPa). Recom-

mended pressure interval in water supply network 2,0 – 5,0 Atm (206 – 515 kPa). Differ-

ence of cold and hot water pressure should not /- 10%. In case of deviation of 

water supply system pressure parameters to the specified values installation of devices for 

pressure increase/reduction is required.

To avoid mechanical (abrasive) particles penetration inside the product it is compulsorily 

required to install filters of 100-300 mk.

Bath/Shower mixer, 
Shower mixer (for installation onto vertical surface). 

1. Disconnect hot and cold water supply system

2. Remove (screwloose) aerator (to avoid aerator clogging during first water startup).

3. Fix mixer at the sanitary ware using fitting included into the delivery set.

4. Connect mixer to the water supply system. Switch on water supply system. Check 

leakproofness of all connections during mixer closed position. When necessary arrange 

additional tightening and sealing of connections (when closing valves of supply pipelines 

are closed).

5. Open cold and hot water supply for short period of time (for washing of pipes), then 

close the water supply and install (screw tight) the aerator.

F8010000

F8020000

Summary of Contents for LIKE F8002100

Page 1: ...32 4 5 100 300 1 CLOTH LIKE...

Page 2: ...2 F8082100 F8002100 F8010000 F8092100 F8093000 F8020000 31 100 300 1 150mm 2 3 150mm Spirit Level 37 44 mm...

Page 3: ...30 0 5 6 0 50 620 2 0 5 0 206 515 10 F8010000 F8020000 3 F8002100 F8093000 Instructions for mixer installation Kitchen mixer Basin mixer Bidet mixer for installation onto the horizontal surface ENG...

Page 4: ...stallation 1 Disconnect hot and cold water supply system 2 Remove screwloose aerator to avoid aerator clogging during first water startup 3 Fix mixer at the sanitary ware using fit ting included into...

Page 5: ...rs of 100 300 mk Bath Shower mixer Shower mixer for installation onto vertical surface 1 Disconnect hot and cold water supply system 2 Remove screwloose aerator to avoid aerator clogging during first...

Page 6: ...e eli zamontowa przed bateri na rury wodoci gowe filtry 100 300 mk zapobiegaj ce dostaniu si do wn trza baterii cz stek obcych rdza piasek itd eby zapobiec pojawieniu si na korpusie baterii plam osad...

Page 7: ...cause damages of decorative cover In case of their penetration onto the mixer housing it should be thoroughly cleaned with clean water To avoid damages of product surface it is forbidden to use abras...

Page 8: ...w 100 300 mk Bateriadlawanny dla instalacji na powierzchni pionowej Zakres roboczy ci nienia w sieci wodoci gowej wynosi 0 5 6 0 atm 50 620 kPa Zaleca ny zakres ci nienia w sieci wodoci gowej 2 0 5 0...

Page 9: ...rury nast pnie wy cz dop yw wody i zainstaluj zakr perlator 9 Druckintervall im Wasserleitungsnetz 0 5 6 0 atm 50 600 kPa Druckintervall im Wasserleitungsnetz 2 0 5 0 atm 206 600 kPa Druckunterschied...

Page 10: ...600 kPa Empfohlenes Druckinter vall im Wasserleitungsnetz 2 0 5 0 atm 206 600 kPa Druckunterschied Warm Kaltwas ser darf maksimal 10 betragen Falls die Wasserleitungsnetzdruckparameter von den angege...

Page 11: ...die Rohrleitungsausg nge des Wasserversorgungssystems ein verdichten Sie vorherig das Gewindeteil mit Isolierung W hlen Sie die Position der ausmittigen bergangsst cken bei deren sie zusammenfallen u...

Page 12: ...derung des Schmuckbelages zu vermeiden d rfen keine aggressiven chemischen S uren Alkalien Azeton Ammoniumchlorid und weiteren chlorhaltigen Komponenten zur Pflege verwendet werden K chenmischer Wasch...

Page 13: ...20 100 300 i 0 5 6 0 50 620 2 0 5 0 206 515 10 F8010000 F8020000 13 F8002100 F8093000 RUS...

Page 14: ...0 50 620 2 0 5 0 206 515 10 100 300 1 2 3 4 35mm Min 38mm Max Hot 5 19 0 5 6 0 50 620 2 0 5 0 206 515 10 100 300 i 1 i i 2 i i i i i 3 i i i i i i i 4 i i i i i i i i i i i i i i i 35mm Min 38mm Max...

Page 15: ...18 F8002100 F8093000 I i i i UA 15 100 300 0 5 6 0 50 620 2 0 5 0 206 515 10 F8010000 F8020000...

Page 16: ...16 1 150 150mm Spirit Level 37 44 mm 17 2 3 100 300 4 5 6 7 CLOTH...

Reviews: