MST Installation Instructions
Page 18 [email protected] +1(909) 591-8431 www.alvaradomfg.com
Installation Instructions
Turnstile Control Board Layout
Fig. 29
LEGEND
Item
Name
A
CCW Test Activation Switch (SW7)
B
Access Control Activation - CCW
C
Access Control Activation CW
D
CW Activation Test Switch (SW6)
E
DIP Switches (SW4)
F
Green LED
G
Fire Alarm System Connection - CW
H
Fire Alarm System Connection - CCW
Clockwise Fail Lock
Counterclockwise Fail Lock
Timer - See Chart to the Right
Timer - See Chart to the Right
Feedback Pulse - 100ms
JS3 LED Option
STD Optics
AUX (Fire Alarm Input - N.O.)
Clockwise Fail Safe
Counterclockwise Fail Safe
Timer - See Chart to the Right
Timer - See Chart to the Right
Feedback Pulse - 300ms
JS2 LED Option
1
st
Sensor Optics
AUX (Fire Alarm Input - N.C.)
SW4 Layout
1
2
3
4
5
6
7
8
ON
DIP
A
C
G
D
E
J18
J3
J7
J4
J10
J9
J5
J8
J2
SW4
F
X 5 R G Y
X 5 R G Y
CCW CCW CW CW
CCW CW
CCW
-CNT
CW
-CNT
OPTICAL
SENSORS
CNT
-RESET
J19
SW3
J11
B
H
ACC GND REJ CLS GND OPN CNT COM
ACC GND REJ CLS GND OPN CNT COM
TIMED DELAY RESET TIMER (Positions
T3 and T4)
T3
T4
5 seconds
10 seconds
15 seconds
20 seconds (Default)
ON
ON
ON
OFF
OFF
ON
OFF
OFF
Entry Time Adjusting Control Switch Settings
JP1
J14
JP2
J17
J15
Fig. 29A
Fig. 29B
SW7
SW6
NOTE
Default DIP switch settings pictured
above are for Fail-lock/Fail-safe
configurations.