CONTROL UNITS СU-TR230-868 / СU-TR400-868
20
20
SETTINGS
MENU
SETTING
dESCRIPTION
VaLUES
faCTORy
VaLUE
P1
f7
*
Setting to disable the built-in obstacle detection system when opening
(
P5
–
f1
).
Designed to avoid false positives when using the built-in obstacle detection system
(
P5
–
f1
) in the unit when opening the doors. The position of the beginning of contact
of the damper (springs) of doors located at the end of opening is adjusted. From this
position until fully opening, the
P5
–
f1
setting will be disabled.
After entering the setting using
or
set the doors to the desired
position and press
to confirm the set position. The inscription
P
will appear
with a dot (
P.
) on the display
f9
Time of partially opening.
Opening is
performed from the end position of the
closed doors by the input command
P
(
tab.
2,
connector 20) or by the command of the
remote control PARTIALLY OPEN (
tab.
4)
no
— disabled
01
,
02
,
03 … 30
:
01
— 1 s
30
— 30 s
no.
P2
Radio control setting.
See section ‘6.2. Radio control setting’
P3
f1
Manual operation mode.
The movement is
performed by pressing and holding the control
device: only unit buttons
and
(
Figure
7),
and
(
Figure
8, 9) connection
inputs
OP
and
CL
(
tab.
2, connector 20). To stop
or block the start of movement, only the unit
buttons are active
and
, input
S
. The
remote controls do not work
no
— disabled
on
— enabled
on.
Y
In manual operation mode the control unit and other control devices must be located
in a place that provides a good overview of the door movement. In the case of access by
unauthorized persons, control for them should be impossible, for example, by installing
a switch with a key (
tab.
2, connector 17).
aTTENTION!
If manual operation mode is disabled, then mandatory use of safety devices
(systems) of
C
and
d
, or
E
type (EN 12453) is required. The selection of a solution (safety
edge and photocells, photo rulers or another) and execution of works (installation, setting,
verification) is carried out by qualified specialists of the competent organization.
f3
Collective mode of operation.
Depending on
whether the mode is on or off, the operation
logic of the
SBS
connection input (
tab.
2,
connector 20) and the STEP BY STEP command
of the radio remote control differ (
tab.
4).
Enabled:
with commands there will be a sequence
of operation ‘Open — Close — Open — Close
…
’.
When opening, the commands are not executed.
When closing, the command will cause a stop of
movement and subsequent full opening.
Disabled:
with commands there will be a se-
quence of work ‘Open — Stop — Close — Stop —
Open
…
’
no
— disabled
on
— enabled
no.
f4
Output Connector 7 Operation
(
tab.
2)
no
— disabled
01…16
— are described
in
tab.
14
no.
f5
Output Connector 8 Operation
(
tab.
2)
f6
Output Connector 9 Operation
(
tab.
2)
Summary of Contents for CU-TR230-868