- 9 -
PROGRAMING MANUAL FOR DM MOTORS, SERIES EV/Y
1
Production plant in Opole
ul.
Gosławicka 3, 45
-446 Opole, Poland
tel. +48 77 40 00 000, fax. +48 77 40 00 006
e-mail: [email protected]
Technical data
- power supply: 230 VAC / 50 Hz
- electronic limit swiches
- obstacle detection
- bulid in radio receiver
- frequency transmission rate: 433.92MHz
- output power: 10 milliwatts (mW)
- operating temperature: ~ -10
o
C ~ +50
o
C (protection degree IP44)
- transmission distance: 200 meters (open area)
35 meters (built-up area)
- ability to store up to 20 channels in one tubular motor. Each next channel will
erase the first one
- possibility to control by remote control or by the two-way swich in step by
step system
All DC series transmitters available in the ALUPROF offer are suitable
for the radio control.
The manufacturer reserves a margin tolerance with respect to the catalogue
data due to use in a variety of conditions.
Headquarters; Production plant in Bielsko-
Biała
Warszawska 153, 43-300 Bielsko-
Biała, Poland
+48 33 81 95 300, fax. +48 33 82 28 512
PROGRAMING MANUAL FOR DM MOTORS, SERIES EV/Y
Power 230V / 50 Hz
NOTE
- Installation of the motor should be carried out
by authorized persons
- The motor is designed for use in dry rooms and
should not be exposed to direct weather conditions.
- The motor should be powered by a separate circuit
and protected by a quick fuse for example: circuit
breaker type B10
Electrical connections
"
In accordance with the provisions of the Directive of the European Parliament and of the Council 2012/19 / EU of 4 July 2012 on
waste electrical and electronic equipment (WEEE), it is prohibited to place of used equipment together with other wastes, marked
with crossed out wheeled bin symbol.
The users are obliged to transfer their used equipment to a designated collection point for
proper processing. The marking means, at the same time, that the equipment was put on the market after 13 August 2005.
These legal obligations have been introduced to reduce the amount of waste generated from waste electrical and electronic
equipment and to ensure an appropriate level of collection, recovery and recycling. The equipment does not contain any dangerous
components, which would have any particularly negative impact on the environment and human health."
After connecting the tubular motor to the power supply, 3 beeps will be heard immediately (3x BIP), and if he contains a remote
controller in the memory he will make a short movement up and down.