background image

Pro Tips

Wire can be hidden

 by running the wires through a hole behind the wall mounting plate and along 

the back side of the drywall to a location with an outlet.

Switching to battery only power mode

 can be done by restarting the keypad with the battery 

power. First, remove wall power supply and batteries. Wait 10 seconds. Then, power the keypad 

back up with only batteries. In battery only power mode, AC failure will not be indicated.

Unenrollment 

can be done by following the same steps as enrollment.

Force unenroll 

can be done when no panel is present. Hold the 1 and 3 keys simultaneously to 

enter unenrollment mode. After the keypad fails to unenroll, hold the 1 and 3 keys simultaneously 

again to force unenroll.

AC loss 

will cause an AC fail trouble condition after 1 minute and will switch to battery operation 

blinking display after 10 minutes of continued AC loss.

Adjust blink rate 

by holding the Instant Arm button and pressing the * or # key. This can only be 

done when the device is operating in battery only mode and is not tampered. Blink interval 

options are Off, 10 seconds (default), 5 seconds, and 2.5 seconds. A portion of the light bar will 

illuminate to indicate how much feedback will be given.

Specifications

Physical 

Wall Dimensions
Table Top Footprint
Weight
Mounting Fasteners

Pilot Hole for Screw into Wood
Pilot Hole for Wall Anchor

3.81 x 5.10 x 1.55 inches (9.68 x 12.94 x 3.94 cm) 
3.81 x 5.47 x 3.17 inches (9.68 x 13.89 x 8.05 cm)
1.49 lb (675 g) 

#6 screws & 2 wall anchors (included)
Ø 1/8 in (3 mm)

Ø 3/16 in (4.7 mm)

Environmental

Operating Temperature

Maximum Humidity

32 to 120°F  (0 to 49°C)
85% relative humidity non-condensing

Device Specifications

Frequency
Power Supply

Input
Output
Part Number

Replacement Battery
Nominal Battery Life
Current Draw
Transmitted Indications

2.4 GHz

100-240VAC, 50/60Hz, 0.5A
12VDC, 1A
RE012-6
4 AA batteries 
1 year (Battery only operation under normal use)

350mA (Maximum)

Low Battery, Supervision, Tamper, AC Fail

Certification

RE663

FCC, IC

Specifications subject to change without notice.

IC NOTICE

This device complies with Industry Canada license-exempt RSS 

standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and

(2) This device must accept any interference, including interference 

that may cause undesired operation of the device.

Le présent appareil est conforme aux cnr d’Industrie Canada 

applicables aux appareils radio exempts de licence. L’exploitation 

est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et

(2) L’utilisateur de l’appareil doit accepter tout brouillage 

radioélectrique subi, même si le brouillage est susceptible d’en 

compromettre le fonctionnement.

IC: 8310A-RE663

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is 

subject to the following two conditions:
(1) This device may not cause harmful interference.

(2) This device must accept any interference that may be received, 

including interference that may cause undesired operation.

Changes or modifications not expressly approved by Alula could void 

the user’s authority to operate this equipment.

FCC ID: U5X-RE663

TRADEMARKS

Alula and are trademarks owned by Alula Holdings, LLC.

47-00012 • REV A • 2021-04-13

Tech Support Line • (888) 88-ALULA • (888) 882-5852

alula.com

01