Chapter 6. The Firmware Upgrade Utility
61
Firmware Upgrade Recovery
If the firmware upgrade procedure is unnaturally aborted (due to a power
outage, for example), the switch that was being upgraded at the time may
become inoperable, and may be incapable of accepting a normal firmware
upgrade.
If this occurs, to recover, do the following:
1. Slide the unit's
Firmware Upgrade Recovery Switch
(see page 7), to the
RECOVER position.
2. Perform a warm reset (see
System Reset Button
, page 7).
The switch is now ready to be upgraded.
3. Slide the Recovery Switch back to the NORMAL position.
4. Start the firmware upgrade procedure again (see page 57).