background image

- 2 -  

Trove1 Mercury Kits Installation Guide

Overview:

Altronix Trove Mercury kits are pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/charger 

and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to four (4) doors in a single enclosure.

Configuration Chart:

Altronix

Model

Number

120VAC 60Hz Input Current (A)

Power Supply Board Input Fuse Rating

Power Supply Board Battery Fuse Rating

Nominal DC

Output Voltage

Maximum 

Supply Current

for Main and 

Aux. Outputs

on Power 

Supply board

and ACM4/

ACM4CB

Access Power 

Controller’s

outputs (A)

Fail-Safe/Fail-Secure or Dry Form “C” Outputs

Fail-Safe/Fail-Secure Outputs (auto-resettable)

Current Per ACM4 Output 

(A)

Current Per ACM4CB Output 

(A)

ACM4/ACM4CB Board Input Fuse Rating

ACM4 Board Output Fuse Rating

ACM4CB Board Output PTC Rating

PDS8/PDS8CB Board Input Fuse Rating

PDS8 Board Output Fuse Rating

PDS8CB Board Output PTC Rating

[DC]

[Aux]

24VDC Output Range (V)

24VDC Output Range (V)

T1MK1F4

3.5

5A/

250V

7.5A/

32V

20.28-

26.4

20.28-

26.4

24VDC @ 3.6A

4

2.5

10A/

250V

3A/

250V

T1MK1F4D

3.5

5A/

250V

7.5A/

32V

20.28-

26.4

20.28-

26.4

24VDC @ 3.6A

4

2.0

10A/

250V

2.0A

T1MK1F4S

3.5

5A/

250V

7.5A/

32V

20.28-

26.4

20.28-

26.4

24VDC @ 3.6A

4

2.5

10A/

250V

3A/

250V

10A/

250V

3A/

250V

T1MK1F4SD

3.5

5A/

250V

7.5A/

32V

20.28-

26.4

20.28-

26.4

24VDC @ 3.6A

4

2.0

10A/

250V

2.0A 10A/

250V

2.0A

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having jurisdiction. 

Product is intended for indoor use only. 

1. Remove backplane from enclosure. Do not discard hardware.

2. Mark and predrill holes in the wall to line up with the top two (2) keyholes in the enclosure. Install two upper fasteners and screws 

  in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure.

  Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the

  enclosure’s upper keyholes over the three upper screws. Install the two lower screws and make sure to tighten all screws.

3. Mount included UL Listed tamper switch (Altronix Model T112 or equivalent) in desired location, opposite hinge. 

  Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side 

(Fig. 1, pg. 2)

  Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. 

  To activate alarm signal open the door of the enclosure.

4. Position Mercury access controller modules over corresponding spacers and depress onto 

  snap on spacers, 

Fig. 2, pg. 3.

5. Refer to the 

eFlow Power Supply/Charger Installation Guide

 for eFlow4NB, 

  and corresponding Sub-Assembly Installation Guide for ACM4(CB), PDS8(CB)

  and VR6 for further installation instructions.

6. Mount backplane to enclosure with hardware.

Hardware:

Snap On Spacer

 |            5/16” Pan Head Screw |         Lock Nut

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Summary of Contents for Trove T1MK1F4

Page 1: ...M4CB PTC Access Power Controller T1MK1F4SD 4 Door Kit with PTC Outputs Fully assembled kit includes Trove1 enclosure with TM1 Altronix Mercury backplane 1 eFlow4NB Power Supply Charger 1 VR6 Voltage Regulator 1 ACM4CB PTC Access Power Controller 1 PDS8CB Dual Input Power Distribution Module Rev T1MK022719 Installing Company __________________________ Service Rep Name ______________________________...

Page 2: ...be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two 2 keyholes in the enclosure Install two upper fasteners and screws in the wall with the screw heads protruding ...

Page 3: ...M4 CB T1MK1F4 and T1MK1F4D Configuration of Mercury Boards 1 Fasten snap on spacers onto metal pems configuration A B C or D of backplane depending on the access controller Fig 2 pg 3 2 Position access controller module over corresponding spacers and depress onto snap on spacers Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercu...

Page 4: ...6 OUT7 OUT8 1 2 3 4 5 6 7 8 Out2 1 off 2 Out3 1 off 2 Out4 1 off 2 Out5 1 off 2 Out6 1 off 2 Out7 1 off 2 Out8 1 off 2 T1MK1F4S and T1MK1F4SD Configuration of Mercury Boards 1 Fasten snap on spacers onto metal pems configuration A B C or D of backplane depending on the access controller Fig 3 pg 4 2 Position access controller module over corresponding spacers and depress onto snap on spacers Fig 3...

Page 5: ... RMR LINQ2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output state change and unit temperature Access control and user managment Restrict read write Restrict users to specific resources Two 2 integr...

Page 6: ... 6 Trove1 Mercury Kits Installation Guide Notes ...

Page 7: ... 7 Trove1 Mercury Kits Installation Guide Notes ...

Page 8: ... 9mm 6 5 165 1mm 1 5 38 1mm 8 5 215 9mm 6 5 165 1mm 4 5 114 3mm 13 0 330 2mm 0 6 15 2mm 14 5 321 3mm 1 45 36 8mm 7 25 184 2mm 1 95 49 5mm 1 1 27 9mm 0 6 15 2mm 0 57 14 5mm 18 0 457 2mm 1 25 31 8mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warran...

Reviews: