1-  Place unit at desired location and secure with mounting
 screws 

(not included) (Fig. 3, pg. 7).

   

Fig. 3

Pole Mounting Using Optional Pole Mount Kit PMK1 

(not included)

:

Note:  In order to properly mount ReServ WP on a pole using Altronix PMK1, additional holes need to be 
   

drilled in the enclosure’s flanges, so the distance between those holes is 10”.

This installation should be made by qualified service personnel. This product contains no serviceable parts. 
PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 
and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included).
1.  Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 4, pg. 7).
2.  Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open 
  end of the strap through the locking mechanism on the strap, then tighten the screw with
  flat head screwdriver or 5/16” hex socket driver (Fig. 5, pg. 7 and Fig. 7, pg. 7).

3.  Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the 
  bracket, tightening bolts with a 7/16” hex socket (Fig. 6, pg. 7).
4.  Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket 
  (Fig. 4, pg. 7).
5.  Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket,
  tightening bolts with a 7/16” hex socket (Fig. 6, pg. 7).
6.  Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking 
  mechanism on the strap, then tighten screw with flat head screwdriver or 5/16” hex socket driver 
  (Fig. 4, pg. 7).
7.  Clip excess straps.

Fig. 4

Fig. 5

Fig. 6

Fig. 7

Fig. 8
2” to 8”(50.8mm to 203.2mm)
diameter round pole

Fig. 8a
5” (127mm) square pole

Summary of Contents for ReServ1WP

Page 1: ... and Four 4 regulated 12VDC outputs 4A total supply current 24VAC and 2A total supply current 12VDC PTC protected power limited outputs ReServ2WP Sixteen 16 true sine wave regulated 24VAC outputs 4A total supply current PTC protected power limited outputs ReServ3WP Sixteen 16 regulated 12VDC outputs 8A total supply current PTC protected power limited outputs ...

Page 2: ...pecifications Output PTC protected power limited outputs are rated 1A Battery Backup Built in charger for sealed lead acid or gel type batteries Automatic switchover to stand by battery when AC fails Supervision AC fail supervision form C contacts Low battery supervision form C contacts Visual and Audio Indicators AC DC power LED indicators Individual power output LED indicators Low voltage input ...

Page 3: ...minals marked P 1 4 N 1 4 Fig 1 pg 5 Connect 24VAC cameras devices to the terminals marked 5 16 Fig 1 pg 5 ReServ2WP Connect 24VAC cameras devices to the terminals marked 1 16 Fig 1 pg 5 ReServ3WP Connect 12VDC cameras devices to the terminals marked P 1 16 N 1 16 Fig 2 pg 6 10 Connect batteries to the terminals marked BAT Figs 1 2 pg 5 6 Use two 2 12VDC batteries connected in series for 24VDC ope...

Page 4: ...ery Terminal Identification Power Supply Board Terminal Legend Function Description L G N Connect 115VAC 60Hz to these terminals L to hot N to neutral DC 24VDC non power limited output AC FAIL NO C NC Form C dry contacts used to instantaneously signal the loss AC to local annunciation devices With AC present terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals ma...

Page 5: ...of used batteires according to the instructions 12VDC Rechargeable Battery order separately Note Two 2 12VDC rechargeable batteries connected in series required Supervised Non power limited Unswitched 115VAC 60Hz 3 5A power mains non power limited Green Lead L G N BAT DC NC C NO NC C NO Input 24VDC power limited Non power limited ...

Page 6: ...rechargeable batteries connected in series required Supervised Non power limited Unswitched 115VAC 60Hz 3 5A power mains non power limited L G N BAT DC NC C NO NC C NO power limited Non power limited 12VDC Power Limited Outputs 24VDC P N 1 OUT 2 1 2V adjust P N 3 OUT 4 3 4V adjust P N 5 OUT 6 5 6V adjust P N 7 OUT 8 7 8V adjust P N 9 OUT 10 9 10V adjust P N 11 OUT 12 11 12V adjust P N 13 OUT 14 13...

Page 7: ...op Pole Mount bracket is achieved tighten the straps down by sliding open end of the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 5 pg 7 and Fig 7 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig...

Page 8: ...17 53 x 15 3 x 6 67 445 3mm x 388 6mm x 169 4mm FRONT VIEW COVER REMOVED RIGHT SIDE VIEW FRONT VIEW END VIEW SECTION A A A A 316 STAINLESS STEEL PADLOCK LATCH ATTACHED WITH RIVETS Ø 375 PADLOCK EYE 17 36 441 mm 12 00 304 8mm 6 41 162 8mm 10 32 X 250 BRASS INSERT 4 PLCS 14 54 369 3mm 16 74 425 2mm 0 125 3 2mm 14 25 362mm 14 00 355 6mm 12 23 310 6mm 17 53 445 3mm 16 00 406 4mm 1 67 42 4mm 5 00 127mm...

Reviews: