Overview:

ReServWP Outdoor Video Surveillance UPS units are designed to provide power for 24VAC and/or 12VDC 
cameras during normal or power outage conditions. 
True sine wave regulated AC outputs and/or regulated DC outputs.

ReServWP Series Outdoor Video Surveillance UPS 

Configuration Reference Chart:

Altronix
Model
Number

Output/Supply

Current (A)

Ambient

Temperature

Input

Rating

PTC Protected 

Auto-Resettable

Power-Limited Outputs

24VAC Outputs

12VDC Outputs

Agency 

Listings

UL Listings and

File Numbers

ReServ1WP

24VAC @ 4A (100VA)

and 12VDC @ 2A

-33ºC to 30ºC

115VAC,

60Hz,

3.5A

16

12

4

UL File # E329542

UL 60950-1

UL/CUL Listed

for Information

Technology

Equipment.

UL 60950-22

Information 
Technology 

Equipment - Safety -

Part 22: Equipment 

to be Installed 

Outdoors

24VAC @ 3.5A (85VA)

and 12VDC @ 2A

-33ºC to 42ºC

ReServ2WP

24VAC @ 4A (100VA) -33ºC to 30ºC

16

16

24VAC @ 3.5A (85VA) -33ºC to 42ºC

ReServ3WP

12VDC @ 8A

-33ºC to 42ºC

16

16

Specifications:

Output:

•  PTC protected power-limited outputs are rated @ 1A.

Battery Backup:

•  Built-in charger for sealed lead acid or 
  gel type batteries. 
•  Automatic switchover to stand-by battery 
  when AC fails.

Supervision:

•  AC fail supervision (form “C” contacts). 
•  Low battery supervision (form “C” contacts). 

Visual and Audio Indicators:

•  AC/DC power LED indicators.
•  Individual power output LED indicators.
•  Low voltage input and Shutdown LED indicators.
•  Audio AC Fail and Battery Fail indicator.

Additional Features:

•  True sine wave regulated AC outputs 
  (ReServ1WP and ReServ2WP). 
  Regulated DC outputs 
  (ReServ1WP and ReServ3WP).
•  Unit maintains camera synchronization. 
•  Ease of installation saves time and eliminates 
  costly labor.

Enclosure Dimensions 

(H x W x D)

:

  17.53” x 15.3” x 6.67” 
  (445.3mm x 388.6mm x 169.4mm).
•  NEMA4 / IP66 Rated enclosure.
•  Accommodates batteries: 
  -  up to two (2) 12VDC/7AH batteries or
  -  up to two (2) 12VDC/12AH batteries.

Stand-by Specifications:

Stand-by Batteries

ReServ1WP - 4A (100VA) load at 24VAC and 2A load at 12VDC max.

ReServ2WP - 4A (100VA) max. load at 24VAC
ReServ3WP - 8A (100VA) max. load at 12VDC

Two (2) 12VDC/7AH

45 minutes

Two (2) 12VDC/12AH

90 minutes

Summary of Contents for ReServ1WP

Page 1: ... and Four 4 regulated 12VDC outputs 4A total supply current 24VAC and 2A total supply current 12VDC PTC protected power limited outputs ReServ2WP Sixteen 16 true sine wave regulated 24VAC outputs 4A total supply current PTC protected power limited outputs ReServ3WP Sixteen 16 regulated 12VDC outputs 8A total supply current PTC protected power limited outputs ...

Page 2: ...pecifications Output PTC protected power limited outputs are rated 1A Battery Backup Built in charger for sealed lead acid or gel type batteries Automatic switchover to stand by battery when AC fails Supervision AC fail supervision form C contacts Low battery supervision form C contacts Visual and Audio Indicators AC DC power LED indicators Individual power output LED indicators Low voltage input ...

Page 3: ...minals marked P 1 4 N 1 4 Fig 1 pg 5 Connect 24VAC cameras devices to the terminals marked 5 16 Fig 1 pg 5 ReServ2WP Connect 24VAC cameras devices to the terminals marked 1 16 Fig 1 pg 5 ReServ3WP Connect 12VDC cameras devices to the terminals marked P 1 16 N 1 16 Fig 2 pg 6 10 Connect batteries to the terminals marked BAT Figs 1 2 pg 5 6 Use two 2 12VDC batteries connected in series for 24VDC ope...

Page 4: ...ery Terminal Identification Power Supply Board Terminal Legend Function Description L G N Connect 115VAC 60Hz to these terminals L to hot N to neutral DC 24VDC non power limited output AC FAIL NO C NC Form C dry contacts used to instantaneously signal the loss AC to local annunciation devices With AC present terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals ma...

Page 5: ...of used batteires according to the instructions 12VDC Rechargeable Battery order separately Note Two 2 12VDC rechargeable batteries connected in series required Supervised Non power limited Unswitched 115VAC 60Hz 3 5A power mains non power limited Green Lead L G N BAT DC NC C NO NC C NO Input 24VDC power limited Non power limited ...

Page 6: ...rechargeable batteries connected in series required Supervised Non power limited Unswitched 115VAC 60Hz 3 5A power mains non power limited L G N BAT DC NC C NO NC C NO power limited Non power limited 12VDC Power Limited Outputs 24VDC P N 1 OUT 2 1 2V adjust P N 3 OUT 4 3 4V adjust P N 5 OUT 6 5 6V adjust P N 7 OUT 8 7 8V adjust P N 9 OUT 10 9 10V adjust P N 11 OUT 12 11 12V adjust P N 13 OUT 14 13...

Page 7: ...op Pole Mount bracket is achieved tighten the straps down by sliding open end of the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 5 pg 7 and Fig 7 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig...

Page 8: ...17 53 x 15 3 x 6 67 445 3mm x 388 6mm x 169 4mm FRONT VIEW COVER REMOVED RIGHT SIDE VIEW FRONT VIEW END VIEW SECTION A A A A 316 STAINLESS STEEL PADLOCK LATCH ATTACHED WITH RIVETS Ø 375 PADLOCK EYE 17 36 441 mm 12 00 304 8mm 6 41 162 8mm 10 32 X 250 BRASS INSERT 4 PLCS 14 54 369 3mm 16 74 425 2mm 0 125 3 2mm 14 25 362mm 14 00 355 6mm 12 23 310 6mm 17 53 445 3mm 16 00 406 4mm 1 67 42 4mm 5 00 127mm...

Reviews: