background image

 

- 6 - 

ReServWP

Fig. 2 - ReServ3WP

Ground Lug

Green Lead

CAUTION: Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteires according to the instructions.

12VDC Rechargeable Battery

(order separately)

Note: Two (2) 12VDC rechargeable batteries

connected in series required.

Supervised - Non power-limited

Unswitched

115VAC 

60Hz, 3.5A

power mains

(non power-limited)

L     G     

N

+ BAT --

--  DC + 

NC  C  NO

NC  C  NO

power-

limited

Non power-limited

12VDC

Power-Limited Outputs

---   24VDC   +

P

N

1 OUT 2

1,2 V adjust

P

N

3 OUT 4

3,4 V adjust

P

N

5 OUT 6

5,6 V adjust

P

N

7 OUT 8

7,8 V adjust

P

N

9 OUT 10

9,10 V adjust

P

N

11 OUT 12

11,12 V adjust

P

N

13 OUT 14

13,14 V adjust

P

N

15 OUT 16

15,16 V adjust

Summary of Contents for ReServ1WP

Page 1: ... and Four 4 regulated 12VDC outputs 4A total supply current 24VAC and 2A total supply current 12VDC PTC protected power limited outputs ReServ2WP Sixteen 16 true sine wave regulated 24VAC outputs 4A total supply current PTC protected power limited outputs ReServ3WP Sixteen 16 regulated 12VDC outputs 8A total supply current PTC protected power limited outputs ...

Page 2: ...pecifications Output PTC protected power limited outputs are rated 1A Battery Backup Built in charger for sealed lead acid or gel type batteries Automatic switchover to stand by battery when AC fails Supervision AC fail supervision form C contacts Low battery supervision form C contacts Visual and Audio Indicators AC DC power LED indicators Individual power output LED indicators Low voltage input ...

Page 3: ...minals marked P 1 4 N 1 4 Fig 1 pg 5 Connect 24VAC cameras devices to the terminals marked 5 16 Fig 1 pg 5 ReServ2WP Connect 24VAC cameras devices to the terminals marked 1 16 Fig 1 pg 5 ReServ3WP Connect 12VDC cameras devices to the terminals marked P 1 16 N 1 16 Fig 2 pg 6 10 Connect batteries to the terminals marked BAT Figs 1 2 pg 5 6 Use two 2 12VDC batteries connected in series for 24VDC ope...

Page 4: ...ery Terminal Identification Power Supply Board Terminal Legend Function Description L G N Connect 115VAC 60Hz to these terminals L to hot N to neutral DC 24VDC non power limited output AC FAIL NO C NC Form C dry contacts used to instantaneously signal the loss AC to local annunciation devices With AC present terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals ma...

Page 5: ...of used batteires according to the instructions 12VDC Rechargeable Battery order separately Note Two 2 12VDC rechargeable batteries connected in series required Supervised Non power limited Unswitched 115VAC 60Hz 3 5A power mains non power limited Green Lead L G N BAT DC NC C NO NC C NO Input 24VDC power limited Non power limited ...

Page 6: ...rechargeable batteries connected in series required Supervised Non power limited Unswitched 115VAC 60Hz 3 5A power mains non power limited L G N BAT DC NC C NO NC C NO power limited Non power limited 12VDC Power Limited Outputs 24VDC P N 1 OUT 2 1 2V adjust P N 3 OUT 4 3 4V adjust P N 5 OUT 6 5 6V adjust P N 7 OUT 8 7 8V adjust P N 9 OUT 10 9 10V adjust P N 11 OUT 12 11 12V adjust P N 13 OUT 14 13...

Page 7: ...op Pole Mount bracket is achieved tighten the straps down by sliding open end of the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 5 pg 7 and Fig 7 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig...

Page 8: ...17 53 x 15 3 x 6 67 445 3mm x 388 6mm x 169 4mm FRONT VIEW COVER REMOVED RIGHT SIDE VIEW FRONT VIEW END VIEW SECTION A A A A 316 STAINLESS STEEL PADLOCK LATCH ATTACHED WITH RIVETS Ø 375 PADLOCK EYE 17 36 441 mm 12 00 304 8mm 6 41 162 8mm 10 32 X 250 BRASS INSERT 4 PLCS 14 54 369 3mm 16 74 425 2mm 0 125 3 2mm 14 25 362mm 14 00 355 6mm 12 23 310 6mm 17 53 445 3mm 16 00 406 4mm 1 67 42 4mm 5 00 127mm...

Reviews: