background image

 

- 6 - 

eBridge8PCRX

 

Note: Port 80 is the default port used for web browsing. Because of this, in order to prevent the average user from

 

hosting a web server, most ISPs BLOCK traffic using port 80 from reaching the average site. If you only plan to

 

monitor your eBridge8PCRX on a LAN, you can use port 80, and don’t have to concern yourself with routers.

 

However, if you desire remote access to your eBridge8PCRX, you MUST select functional ports and set up the

 

port forwarding in your router. Other ports, such as 8080 and 8000 are sometimes blocked by ISPs as well.

 

What port(s) should be used? There are 65,535 valid IP ports to choose from.

 

These are broken down into three groups:

 

• Well Known Ports 0 through 1023.

 

• Registered Ports 1024 through 49151.

 

• Dynamic and/or Private Ports 49152 through 65535.

So, rather than encounter a port conflict by choosing a port commonly used for another purpose (like port 25 for SMTP 

mail or port 448 for secure sockets), choose an ‘unusual’ port number. For example, add 50,000 to your house number: 

50,123 is less likely to lead to a port conflict. For a list of the known and registered ports,

see http://www.iana.org/assignments/port-numbers.

Reset Features:

Reset Password:

1.  Remove unit from the rack (Fig. 3, pg. 6).
2.  Remove mounting bracket located to the right of the ethernet port (Fig. 3, pg. 6).
3.  Disonnect two pin plug connector from the jack marked [Input 1] (Fig. 3, pg. 6).
4.  Reconnect two pin plug connector to the jack marked [Input 1] while depressing
  the [RESET button] on the side of the eBridge8PCRX (Fig. 3, pg. 6).

Reset IP to Factory Settings:

1.  Remove unit from the rack (Fig. 3, pg. 6).
2.  Remove mounting bracket located to the right of the ethernet port (Fig. 3, pg. 6).
3.  During normal operation depress the [RESET button] on the side of the eBridge8PCRX for approximately
  1 second (Fig. 3, pg. 6).
4.  Factory settings are: DHCP server and the IP address is [192.168.168.168].

Re

se

t

Etherne

t

Fig. 3

Summary of Contents for eBridge8PCRX

Page 1: ...IP over Coax Receiver Installation Guide Models Include eBridge8PCRX Eight 8 Channel Receiver Rev 072412 More than just power I T E 43KC ...

Page 2: ...e equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to supply circuit and the effect that ...

Page 3: ...ssing equipment is insufficient in speed the image may show pixilation and latency It is advisable to pretest system if unsure Alternatively frame rate and resolution may be reduced to accommodate system equipment Technical Specifications Parameter Description Connections BNC for Coax link RJ45 for ethernet link Input power requirements 48VDC 6A 56VDC 6A Indicators Blue Coax Link Yellow RJ45 conne...

Page 4: ...cture of the Start button clicking Control Panel clicking Network and Internet clicking Network and Sharing Center and then clicking Manage Network connections b Right click the Local Area Connection icon and then click Properties Administrator permission required If you are prompted for an administrator password or confirmation type the password or provide confirmation c Click the Networking tab ...

Page 5: ...work Menu LAN Network Type Static IP User can set a fixed IP for network connection DHCP DHCP server in LAN will automatically an assign IP configuration for the network connection IP This field shows the eBridge8PCRX current IP Address A static IP address must be set manually If DHCP this value will be assigned automatically Subnet Mask This field shows the subnet mask for your network so the eBr...

Page 6: ... port commonly used for another purpose like port 25 for SMTP mail or port 448 for secure sockets choose an unusual port number For example add 50 000 to your house number 50 123 is less likely to lead to a port conflict For a list of the known and registered ports see http www iana org assignments port numbers Reset Features Reset Password 1 Remove unit from the rack Fig 3 pg 6 2 Remove mounting ...

Page 7: ...eBridge8PCRX 7 eBridge8PCRX Rack Mount Chassis Mechanical Drawing Dimensions 1 625 x 19 125 x 8 5 42mm x 486mm x 216mm Fig 4 8 5 216mm 0 75 19 05mm 19 125 486mm 17 625 447 7mm 1 625 42mm ...

Page 8: ...ead screws for mounting brackets Four 4 rubber pads Remove Mounting Options Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 5a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 5b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not include...

Reviews: