eBridge8PCRX

Overview:

The eBridge8PCRX is a CAT5 to Coax cable Managed Ethernet Midspan receiver. The receiver enables fast 10/100Base-T 

Ethernet digital communication to be received over Coax cable. An eBridge8PCRX receiver sends power over the coax to 

the eBridge1PCT 15.4W (PoE) or eBridge1PCTX 30W (PoE+) transmitter under PoE protocol. The eBridge1PCT/PCTX 

in turn delivers that power to a PoE enabled camera or IP device. The eBridge8PCRX will not deliver power to non com-
pliant devices, thus avoiding accidental power turn into improperly connected analog cameras.  These plug and play units 

facilitate system upgrades from analog to IP cameras/devices utilizing existing legacy Coax and eliminating the costs and 

labor associated with installing new network cabling. In addition, data transmission and power over the Coax is possible 

up to 500m in comparison to 100m Ethernet maximum distance (see Maximum Length of Coax Type vs. Camera Power/
PoE Class, pg. 3)
. A maximum range from head end to the PoE camera/device is 610m taking into consideration that up 

to 100m of structured cable may be deployed at each end.

Features:

   Installation  Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and 
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
eBridge8PCRX is not intended to be connected to outside plant leads and should be installed indoors within the protected 
premises. The eBridge8PCRX is intended for indoor use only. This product is intended to be supplied by a UL Listed 
Power Supply rated from 48VDC to 56VDC.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of 
the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equip-
ment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe 
operation of the equipment is not compromised
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved 
due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to supply circuit and the effect 
that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of 
equipment nameplate rating should be used when addressing this concern.
Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be 
given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

Agency Listings:

•  UL/CUL Listed for Information 
  Technology Equipment (UL 60950-1).
•  CE approved.

Input:

•  48VDC to 56VDC UL Listed power supply 
  (attention to observe polarity).
  Note: Use 54V to 56V power supply to achieve full  
  power per IEEE802.3 at standard.

Power Consumption

(per input for max. load; 2 inputs, each powers 8 channels)

:

•  48VDC/6A, 56VDC/6A,
  eBridge1PCTX (30W): Powered by eBridge8PCRX.
  eBridge1PCT (15W): Powered by eBridge8PCRX.

Ethernet:

•  Connectivity: RJ45, auto-crossover.
•  Wire type: 4-pair Cat-5 or better structured cable.
•  Distance: up to 100m.
•  Speed: 10/100BaseT, half/full duplex, auto negotiation.
•  Throughput is rated to pass 25mbps of data at
  distances up to 500m. With proper headend
  equipment multiple Megapixel cameras can be used.

Coax:

•  Distance: up to 500m.
•  Connectivity: BNC, RG-59/U or similar.

LED Indicators:

•  Blue LED - Coax link connection.
•  Yellow and Green LED (RJ45) IP Link status, 
 10/100Base-T/active.
•  Green LED - Power.

Environmental:

•  Operating Temperature: 14ºF to 122ºF (--- 10ºC to +50ºC).
•  Storage Temperature: -- 22º to 158ºF (--- 30º to +70ºC).
•  Humidity: 20 to 85%, non-condensing

Applications:

•  Retrofit digital IP cameras in an analog CCTV 
 installation.
•  Works with Megapixel, HD720, HD1080 and VGA
  (SD) cameras (see note, pg. 2).
•  Extend Network link distance in an industrial
 environment.
•  Upgrade deployed CCTV Coax to a digital network 
  for Retail, Casinos, Airports, Schools, Hospitals, etc.

Mechanical:

•  Dimensions (H x W x D approx.):
  1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm)

Summary of Contents for eBridge8PCRX

Page 1: ...IP over Coax Receiver Installation Guide Models Include eBridge8PCRX Eight 8 Channel Receiver Rev 072412 More than just power I T E 43KC ...

Page 2: ...e equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to supply circuit and the effect that ...

Page 3: ...ssing equipment is insufficient in speed the image may show pixilation and latency It is advisable to pretest system if unsure Alternatively frame rate and resolution may be reduced to accommodate system equipment Technical Specifications Parameter Description Connections BNC for Coax link RJ45 for ethernet link Input power requirements 48VDC 6A 56VDC 6A Indicators Blue Coax Link Yellow RJ45 conne...

Page 4: ...cture of the Start button clicking Control Panel clicking Network and Internet clicking Network and Sharing Center and then clicking Manage Network connections b Right click the Local Area Connection icon and then click Properties Administrator permission required If you are prompted for an administrator password or confirmation type the password or provide confirmation c Click the Networking tab ...

Page 5: ...work Menu LAN Network Type Static IP User can set a fixed IP for network connection DHCP DHCP server in LAN will automatically an assign IP configuration for the network connection IP This field shows the eBridge8PCRX current IP Address A static IP address must be set manually If DHCP this value will be assigned automatically Subnet Mask This field shows the subnet mask for your network so the eBr...

Page 6: ... port commonly used for another purpose like port 25 for SMTP mail or port 448 for secure sockets choose an unusual port number For example add 50 000 to your house number 50 123 is less likely to lead to a port conflict For a list of the known and registered ports see http www iana org assignments port numbers Reset Features Reset Password 1 Remove unit from the rack Fig 3 pg 6 2 Remove mounting ...

Page 7: ...eBridge8PCRX 7 eBridge8PCRX Rack Mount Chassis Mechanical Drawing Dimensions 1 625 x 19 125 x 8 5 42mm x 486mm x 216mm Fig 4 8 5 216mm 0 75 19 05mm 19 125 486mm 17 625 447 7mm 1 625 42mm ...

Page 8: ...ead screws for mounting brackets Four 4 rubber pads Remove Mounting Options Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 5a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 5b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not include...

Reviews: