background image

- 2 - 

eBridge100RM

   Installation  Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and 

with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or 

Recognized wire suitable for the application.

eBridge100TM/eBridge100ST and eBridge100RM are not intended to be connected to outside 

plant leads and should be installed indoors within the protected premises. eBridge100TM, 

eBridge100ST, and eBridge100RM are intended for indoor use only.

Note: The eBridge100RM can be paired with either eBridge100TM or eBridge100ST.

1. 

eBridge100RM installation:

  a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s  

  mounting 

hole 

(Fig. 2a, pg. 3). Unit should be mounted in proximity to ethernet 

    switch/network, NVR or video server.

  

Note: When installing more than one (1) eBridge100RM, please allow at least 1” (25mm)

    distance between the receivers.

 b. 

Connect structured cable from Ethernet midspan or endspan device to RJ45 jack marked  

  [PoE 

Input] 

(Fig. 2, pg. 3).

 c. 

When connecting to the eBridge100 transceiver:

  

Coax: Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).

  

CAT5 or higher: Connect CAT5 or higher to connector marked [RJ45 OUT]  

 

  (eBridge100TM 

only) 

(Fig. 2, pg. 3).

2. 

eBridge100TM installation:

  a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s  

  mounting 

hole 

(Fig. 2a, pg. 3). Unit should be mounted in proximity of camera/device.

  b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2, pg. 3).

 c. 

Coax: Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).

  

CAT5 or higher: Connect CAT5 or higher to connector marked [RJ45 IN] (Fig. 2, pg. 3).

3. 

eBridge100ST installation:

  a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s  

  mounting 

hole 

(Fig. 3, pg. 3). Unit should be mounted in proximity of camera/device.

  b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 3, pg. 3).

 c. 

Coax: Connect Coax cable to BNC flying lead marked [Coax] (Fig. 3, pg. 3).

Note: The eBridge100RMT is designed to accommodate Megapixel, HD720, HD1080 and VGA 

(SD) cameras. It is important to note that some high resolution and high frame rate cameras may 

demand faster headend processing ability, such as a PC graphics card to present a quality image. 

If the headend processing equipment is insufficient in speed, the image may show pixilation and 

latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may 

be reduced to accommodate system equipment.

Technical Specifications:

Parameter

Description

Connections

BNC for Coax link. RJ45 for extended Ethernet link.

Input power 

requirements

Midspan or endspan port connected. PoE compliant to IEEE 802.3af (15W) 

and PoE+ compliant to IEEE 802.3at (30W).

Indicators

Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.

Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.

Yellow: PoE Active.

Environmental 

Conditions

Operating Ambient Temperature: UL60950-1

eBridge100RM: --- 4ºF to 120.2ºF (-- 20ºC to +49ºC).

eBridge100TM: --- 4ºF to 120.2ºF (-- 20ºC to +49ºC).

eBridge100ST:  For 15W: -- 40ºF to 167ºF (--- 40ºC to 75ºC).

                        For 30W: -- 40ºF to 140ºF (--- 40ºC to 60ºC).

Relative humidity: 85%, +/ --- 5%

Storage Temperature: -- 4º to 158ºF (--- 20º to 70ºC.

Operating Altitude: -- 1000 to 6,561.679 ft. (-- 304.8 to 2000m).

Regulatory 

Compliance

UL/CUL Listed for Information Technology Equipment (UL 60950-1).

CE approved. C-Tick compliant.

Weights (approx.) Product:  3.88 oz. (0.11 kg), Shipping: 6.70 oz. (0.19 kg).

Summary of Contents for ebridge100rm

Page 1: ...o IEEE 802 3at 30W Delivered to camera by eBridge100TM Power provided by eBridge100RM to eBridge100TM by PoE protocol Throughput is rated to pass 100mbps of data at distances up to 500m Coax link Distance Coax 300m Maximum Length of Coax Type vs Camera Power PoE Class pg 4 for power delivery Connectivity BNC RG 59 U or similar Coax or CAT5e link Distance CAT5e up to 500m Coax 300m Maximum Length o...

Page 2: ...CAT5 or higher to connector marked RJ45 IN Fig 2 pg 3 3 eBridge100ST installation a Secure unit to desired mounting surface with a proper fastening device utilizing the case s mounting hole Fig 3 pg 3 Unit should be mounted in proximity of camera device b Connect structured cable from IP camera device to RJ45 jack marked PoE Out Fig 3 pg 3 c Coax Connect Coax cable to BNC flying lead marked Coax F...

Page 3: ...E received from eBridge100RM Ethernet Switch NetWay8M Front Panel PoE SHUTDOWN Local Area Network LAN or Laptop connection PoE PoE over Coax CAT5e up to 500m max PoE compliant 100m max 100m max Structured Cable Legend Mounting Hole PoE Camera Coax eBridge100RM eBridge100TM RJ45 OUT PoE LED PoE LED Coax RJ45 LEDs Yellow Speed Green Activity Yellow LED Power and PoE PoE Input I T E 43KC www altronix...

Page 4: ...m RG59U 22awg 30W 300m 167m RG59U 20awg 15W 300m 532m RG59U 20awg 30W 300m 266m RG59U 18awg 15W 300m 846m RG59U 18awg 30W 300m 423m Cat5e 15W 500m 846m Cat5e 30W 500m 423m Ethernet Switch NetWay8M Front Panel PoE SHUTDOWN Local Area Network LAN or Laptop connection PoE Camera PoE Camera PoE Camera PoE Camera 100m max 100m max 100m max 100m max PoE compliant 100m max PoE compliant 100m max PoE comp...

Reviews: