How to clean the chiller interior
Remove the optional roll-in cart (trolley) from cart
equipped models. Open the Quickchiller door to warm
the interior of the cabinet.
1. Remove any loose food debris with a cleaning cloth
or small hand broom.
2. Use a mild, non-abrasive detergent and warm water.
Wipe-down the interior of the cabinet, removing all
food residue. This includes the ceiling, floor, walls
and fan panel.
Wipe-down the interior door panel and clean the
vinyl gaskets. Make certain to clean under the
gaskets to remove any mildew accumulation or food
residue.
3. Rinse all interior surfaces including the cabinet door
and gasket with clean water and a cloth. Remove all
rinse water.
4. Wipe interior surfaces with a clean cloth and
sanitizing solution for use on metal and vinyl food
contact surfaces. This is an important step to control
the build-up of unwanted mildew and mold in the
refrigeration system.
5. Allow interior to air dry with door open.
How to clean the chiller exterior
1. Wipe all exterior surfaces including
the control panel, door frame,
latches, and hinges with a damp
cloth containing a mild, non-
abrasive, non-chloride detergent
solution.
2. Rinse detergent solution with a cloth and warm
water. Allow exterior to air dry.
3. Polish with any standard stainless steel polish
designed for use on food service equipment.
When cleaning the exterior of the cabinet,
always wipe with the grain of the stainless steel
to avoid scratching or marring the finish. Avoid
an accumulation of oil based polish or cleaner
collecting along the edges of the keyboard overlay
on the control box. Oil build-up around the control
overlay could eventually loosen
the panel.
Do not use abrasive cleaning compounds
or implements.
How to clean the probes
1. Remove all food soil from probes between loads
and at the end of each production shift. Wipe entire
probe, cable assembly, and probe holding door
bracket with warm detergent solution and a clean
cloth.
2. Remove detergent by wiping each probe, cable, and
bracket with clean rinse water and a cloth.
3. Wipe probes and probe brackets with disposable
alcohol pad or sanitizing solution recommended for
food contact surfaces
4. Allow probe and cable to air dry in probe holding
door bracket.
5. Wipe the probe with a disposable alcohol pad prior
to inserting into a new food product.
How to clean the roll-in trolley
1. Take food trolley to a cart wash area. Trolleys may
be cleaned using any mild cleaning detergent and
warm water.
2. Hand wipe all framing, slides, drip pan, and base.
Thoroughly clean debris from the casters. A spray
hose can be used for easier cart cleaning.
3. Remove detergent solution with warm water.
4. Wipe or spray with a sanitizing solution designed for
use on metal and vinyl food contact surfaces.
5. Allow trolley to air dry.
How to clean the condenser coils
Keep the condenser coils free of dust and debris build-
up to insure proper air circulation and cooling of the
refrigeration system.
1. Turn power supply to the cabinet OFF.
2. Using a vacuum or small hand broom, brush the
condenser coils in a vertical motion to remove any
accumulated dust or debris.
3. Turn breaker switches ON and replace air grill.
WARNING
To prevent serious personal injury, death, or
property damage:
Do not steam clean, hose down or flood the
interior or exterior with water or liquid solution
of any kind.
Do not use water jet to clean. Failure
to observe this precaution will void the warranty.
WARNING
To prevent serious injury, death, or property
damage,
always disconnect the appliance
from the power source before cleaning
or servicing.