S I T E I N S T A L L A T I O N
I N S T A L L A T I O N
A number of adjustments are associated with
initial installation and start-up. It is important
that these adjustments be conducted by a qualified
service technician. Installation and start-up
adjustments are the responsibility of the dealer or
user. These adjustments include but are not
limited to thermostat calibration, door adjustment,
leveling, electrical hook-up and installation of
optional casters or legs.
LEVELING
Level the oven
from side-to-side and front-to-
back with the use of a spirit level. For ovens
installed with casters, it is important that the
installation surface be level due to the probability
of frequent oven repositioning.
We recommend checking the level of the oven
periodically to make certain the floor has not
shifted nor the oven moved.
NOTE:
Failure to properly level this oven can
cause improper function and will result
in the uneven baking with products
consisting of semi-liquid batter.
RESTRAINT REQUIREMENTS
—MOBILE EQUIPMENT
Any appliance that is not furnished with a power
supply cord but that includes a set of casters must
be installed with a tether. Adequate means must
be provided to limit the movement of this
appliance without depending on or transmitting
stress to the electrical conduit. The following
requirements apply:
1.
Maximum height of casters is 6" (152mm).
2.
Two of the casters must of be the locking type.
3.
Such mobile appliances or appliances on mobile
stands must be installed with the use of a flexible
connector secured to the building structure.
A mounting connector for a restraining device is
located on the lower back flange of the appliance
chassis or on an oven stand, approximately 18"
(457mm) from the floor. A flexible connector is not
supplied by nor is it available from the factory.
W A R N I N G
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.
Summary of Contents for Halo Heat 1200-S
Page 31: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 30 ...
Page 32: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 31 ...
Page 33: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 32 ...
Page 34: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 33 ...
Page 35: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 34 ...
Page 36: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 35 ...
Page 37: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 36 ...
Page 38: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 37 ...
Page 39: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 38 ...
Page 40: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 39 ...
Page 41: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 40 ...
Page 42: ...1200 S 1200 UP INSTALLATION OPERATION SERVICE MANUAL PG 41 ...