E R R O R C O D E S
MN-36008 (Rev. 8) 01/16 • COMBITHERM CT EXPRESS • C-5
Error
Code
Error Call Out in Display
Description of Error
Possible Causes
E11
Convection Temperature
High
Oven cavity temperature N6
too high
— Convection element contactor stuck closed/on.
— Faulty oven temperature probe connection at
relay board.
— Faulty N6 oven temperature probe.
— Faulty relay board.
E13
Boiler Temperature High
Steam generator
temperature too hot
— Immersion element is not submersed in water
due to scale build up on the water level probe/
inside the tank.
— Immersion element contactor stuck closed.
— Faulty B4 steam generator temperature probe
connection at relay board.
— Faulty B4 temperature probe.
E15
Condensor Temperature
High
Condensor water
temperature too high
— Untreated water supply line is disconnected or
shut off.
— Cooling solenoid is not being energized when B3
probe is above set point.
— Faulty B3 condensate temperature probe
connection at relay board.
— Faulty B3 condensate temperature probe.
E20
HACCP Only - B11 Core
Temperature Probe Single
Point Fault
Error E20 is not shown in display.
Instead a probe sign with “?” is
shown as popup window. In case
the customer cooks in time mode
during fi rst step and during second
step switches to probe mode but has
no probe in place, the error E20 will
be shown in the error code list and
HACCP list.
Single point core
temperature probe defect or
disconnected
— Probe not installed inside oven.
— Faulty B11 Single Point Core Temperature probe
receptacle connection at relay board.
— Faulty B11 single point core temperature probe.
— Debris buildup on probe receptacle pins inside of
the oven.
E21
N6 Oven Cavity
Temperature Probe Fault
N6 probe “open”
— Faulty N6 oven cavity temperature probe
connection at relay board.
— Faulty N6 oven temperature probe.
E22
B10 Core Temperature
Probe Multipoint Fault
Multipoint core temperature
probe defect or
disconnected
— Faulty B10 multipoint core temperature probe
connection at relay board.
— Faulty B10 multipoint core temperature probe.
E23
B4 Boiler Probe Fault
B4 probe “open”
— Faulty B4 boiler temperature probe connection at
relay board.
— Faulty B4 boiler temperature probe.
E24
B5 Bypass Probe Fault
B5 probe “open”
— Faulty B5 steam bypass probe connection at
relay board.
— Faulty B5 steam bypass probe.
E25
B3 Condensor Probe Fault
B3 probe “open”
— Faulty B3 condensor probe connection at relay
board.
— Faulty B3 condensor probe.
E26
N8 Immersion Element
Safety Probe Fault
N8 probe “open”
— Faulty N8 safety temperature probe connection at
relay board.
— Faulty N8 safety temperature probe.
E R R O R C O D E S
(CONTINUED ON NEXT PAGE)
Summary of Contents for CT EXPRESS 4 10ESi
Page 30: ...MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS B 14...
Page 31: ...MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS B 15...
Page 116: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 2...
Page 117: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 3...
Page 118: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 4...
Page 119: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 5...
Page 120: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 6...
Page 121: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 7...
Page 122: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 8...
Page 123: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 9...
Page 124: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 10...
Page 125: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 11...
Page 126: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 12...
Page 127: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 13...
Page 128: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 14...
Page 129: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 15...
Page 130: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 16...
Page 131: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 17...
Page 132: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 18...
Page 133: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 19...
Page 134: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 20...
Page 135: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 21...
Page 136: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 22...
Page 137: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 23...
Page 138: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 24...
Page 139: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 25...
Page 140: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 26...
Page 141: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 27...
Page 142: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 28...
Page 143: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 29...
Page 144: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 30...
Page 145: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 31...
Page 146: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 32...
Page 147: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 33...
Page 148: ...WIRING D IA G R A M S MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 34...
Page 149: ...WIRING DIAGRAMS MN 36008 Rev 8 01 16 COMBITHERM CT EXPRESS F 35...