The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “
OFF
” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
After wiring and power connection has been
completed, turn the main power switch to the “
ON
”
position.
The main power switch can be left “
ON
”
for daily use, but should be turned “
OFF
” when
cleaning or performing maintenance or repairs to
the rotisserie.
REGARDING INTERNATIONAL
STANDARD UNITS:
If the unit is not equipped with flexible cord
with plug, an all-pole country approved
disconnection device which has a contact
separation of at least 3mm in all poles must be
incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the
green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol.
If a plug is used, the socket outlet must be easily
accessible. If the power cord needs replacement,
use a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock
hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts to
provide sufficient protection against potential
difference. The terminal is marked with the
following symbol.
E L E C T R I C A L C O N N E C T I O N
THE ROTISSERIE CAN BE HARD WIRED. PERMANENT
WIRING FOR ALL OVENS MUST BE INSTALLED BY A
LICENSED ELECTRICIAN IN ACCORDANCE WITH
APPLICABLE, LOCAL ELECTRICAL CODES.
230V ROTISSERIES FOR HARD WIRING MUST BE
EQUIPPED WITH
AN
EXTERNAL
MAIN
SWITCH
WHICH DISCONNECTS ALL POLES WITH A CONTACT
SEPARATION OF AT LEAST 3MM FOR ALL POLES.
“ WA R N I N G ” R I S K O F F I R E !
Use a UL Listed grounding type plug rated 250 Volts, 50
Amperes, 1 Phase, 3 wire for single phase units and 250 V,
50 A, 3 Phase , 4 wire for three phase units.
Plug to be
selected and installed only by qualified service personnel.
Individual
conductors
are
marked
L
1
,
L
2
,
L
3
when
applicable, N when applicable, and G.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
I N S TA L L AT I O N
A R - 7 E R o t i s s e r i e w i t h A R - 7 V H Ve n t l e s s H o o d O p e r a t i o n & C a r e M a n u a l • 6
D A N G E R
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST BE
EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
E L E C T R I C A L
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
K
W
208 (
AGCY
)
1
60
40.0
8.3
BARE END
NO PLUG
230 (
AGCY
)
1
60
42.0
9.0
240 (
AGCY
)
1
60
38.0
8.8
208 (
AGCY
)
3
60
33.0/ph 8.3
BARE END
NO PLUG
230 (
AGCY
)
3
60
35.0/ph 9.0
240 (
AGCY
)
3
60
32.0/ph 8.8
380-415
(
AGCY
)
3
50/60
24.0/ph 8.8
NO CORD
NO PLUG
380
3
50/60
22.0/ph 7.4
415
3
50/60
24.0/ph 8.8
Summary of Contents for AR-7E
Page 42: ...AR 7E Rotisserie with AR 7VH Ventless Hood Operation Care Manual 41 ...
Page 43: ...AR 7E Rotisserie with AR 7VH Ventless Hood Operation Care Manual 42 ...
Page 44: ...AR 7E Rotisserie with AR 7VH Ventless Hood Operation Care Manual 43 ...
Page 45: ...AR 7E Rotisserie with AR 7VH Ventless Hood Operation Care Manual 44 ...