![Alto-Shaam 500-1D MARINE Operation And Care Manual Download Page 8](http://html1.mh-extra.com/html/alto-shaam/500-1d-marine/500-1d-marine_operation-and-care-manual_2912370008.webp)
O & C M A N UA L • D R AW E R WA R M E R
P G . 7
O P E R AT I O N - E L E C T R O N I C C O N T R O L - O P T I O N
POWER INDICATOR LIGHT
UP
/
DOWN
ARROWS
ON
/
OFF POWER KEY
LOCK INDICATOR
LED DISPLAY
HEAT INDICATOR
LIGHT
ON/OFF KEY
Press the on/off key once and the power indicator light will
illuminate. Press and hold the on/off key until the LED
display turns off (at least three seconds) and on/off
indicator goes out.
UP/DOWN ARROW KEY
The up and down arrow keys are used for a variety of
settings when selecting the holding temperature. If an arrow
key is pressed and released the display will show the current
set temperature for two seconds. If an arrow key is held (at
least eight seconds), the value will change at a rapid rate. If
the arrow key is pressed and released in rapid succession, the
set temperature will change by increments of one degree.
ENABLE/DISABLE BEEPER
A beeper sounds when an error code is displayed.
To choose between beeper on and beeper off mode, the
control must be OFF, then press and hold the down arrow
key until either "ON" or "OFF" is shown in the LED display.
Release arrow key when desired mode is displayed.
FAHRENHEIT / CELSIUS
With the control OFF, to choose between Fahrenheit and
Celsius, press and hold the up arrow key until either
°F or °C is shown in the LED display. Release key when
desired setting is displayed.
The control has a four-digit LED display. When the display
is ON, it will show current holding temperature, as well as
diagnostic information.
CONTROL LOCK
The warmer controls can be locked so that no changes can
be made to the set temperature.
To
lock the display
, press and hold the ON/OFF key and
the Up Arrow key at the same time. The lock indicator will
illuminate. When the lock indicator is illuminated,
additional programming will not be functional other than
the key sequence required to unlock the panel.
To
unlock the display
, press and hold the ON/OFF key and
the Down Arrow key at the same time. The lock indicator
will extinguish. The panel keys will resume normal function.
1. Preheat at 200°F (93°C) for 30 minutes.
Press the ON key, and set the temperature to
200°F (93C°) by using the UP/DOWN arrow
keys. Allow a minimum of 30 minutes
preheating time before loading the drawer
warmer with food. The LED heat indicator
light will go “OUT” after approximately 30
minutes preheat time, or when the air
temperature inside the unit reaches the
temperature set by the operator.
2. Load with pans of hot food only.
The purpose of the warmer is to maintain hot
food at proper serving temperature. Only hot
food should be placed into the unit. Before
loading with food, use a food thermometer to
make certain all products are at an internal
temperature range of 140° to 160°F (60° to
71°C). Any food product not within the
proper temperature range should be heated
before loading into the unit.
3. Reset the control to 160°F (71°C).
Check to make certain the drawer is securely
closed, and reset to 160°F (71°C) by using the
UP/DOWN keys.
THIS WILL NOT NECESSARILY BE THE
FINAL SETTING.
The proper temperature range will depend on
the type and quantity of product. When
holding food for prolonged periods, it is
advisable to periodically check the internal
temperature of each item with a food
thermometer to assure maintenance of the
proper temperature range of
140° to 160°F (60° to 71°C).
°F /°C
Summary of Contents for 500-1D MARINE
Page 21: ...O C MANUAL DRAWER WARMER PG 20 ...