T R O U B L E S H O O T I N G C H E C K L I S T
IN STA L L ATION / OPERATION / SERVIC E MA N UA L • 15.
S E R V I C E
TROUBLE
POSSIBLE CAUSE
REMEDY
Unit does not operate.
Insufficient power supply.
Check power source.
Defective power cord or plug.
Check and replace if necessary.
No display in electronic control.
Faulty power supply board.
Check line voltage for 12V across
pins 7 and 8 on the power supply board
and across pins 1 and 2 on connector J3
on the electronic control.
Faulty electronic control.
Replace control.
Cannot control temperature but
Faulty relay
Replace relay.
sensor and electronic control
checks O.K.
Heating element grounded.
Replace element.
Temperature readout incorrect.
Dirty or faulty sensor.
Check sensor at 32°F (0°C).
If Ohm reading is 100,
Faulty control.
replace control.
If Ohm reading is not 100,
replace sensor.
E L E C T R O N I C C O N T R O L
Repairs should be made by authorized service agents only.
includes:
Cable Heating Element . . . . . . . . . . . . . . . . . 108 feet
Ring Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Insulation Corner . . . . . . . . . . . . . . . . . . . . . . . 1 foot
Shoulder Bushing. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cup Bushing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Hex Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Insulating Sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical Tape . . . . . . . . . . . . . . . . . . . . . . . . . . 1 roll
C A B L E H E A T I N G S E R V I C E K I T No.
(one kit per compartment)