MN-29758 (Rev. 6) 05/15 •
TH/III-SK/III Series Cook, Hold, Smoke •
13
e l e c t r I c a l c o n n e c t I o n
I n s t a l l a t I o n
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “OFF” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord and
plug, an all-pole country approved disconnection
device which has a contact separation of at least
3mm in all poles must be incorporated in the fixed
wiring for disconnection. When using a cord
without a plug, the green/yellow conductor shall
be connected to the terminal which is marked with
the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained
from the distributor.
d a n g e r
Ensure power source matches
voltage identified on appliance rating
tag. The rating tag provides essential
technical information required for any
appliance installation, maintenance
or repairs. Do not remove, damage or
modify the rating tag.
d a n g e r
This appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence
of local codes, with the current
edition of the National Electrical
Code ANSI/NFPA No. 70. In Canada,
all electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
Failure to observe this precaution
may damage the appliance,
result in electrical shock, fire or
personal injury.
note
:
Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a country
certified external allpole disconnection switch with
sufficient contact separation.
If a power cord is used for the connection of the product an
oil resistant cord like H05RN or H07RN or equivalent must
be used.
d a n g e r
Appliances with no cord provided
by factory must be equipped with a
cord of sufficient length to permit the
appliance to be moved for cleaning.
Electrical connections must be made
by a qualified service technician in
accordance with applicable electrical
codes. Use the correct AWG wire size
based on the electrical requirements
for the appliance.
Failure to observe this precaution
may result in electrical shock,
damage to the appliance, fire,
property damage or personal injury.
For CE approved units:
To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity,
an equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances/metal parts
to provide sufficient protection against potential
difference. The terminal is marked with
the following symbol.
Summary of Contents for 1000-SK/III
Page 47: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 45 ...
Page 48: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 46 ...
Page 49: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 47 ...
Page 50: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 48 ...
Page 51: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 49 ...
Page 52: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 50 ...
Page 53: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 51 ...
Page 54: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 52 ...
Page 55: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 53 ...
Page 56: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 54 ...
Page 57: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 55 ...
Page 58: ...MN 29758 Rev 6 05 15 TH III SK III Series Cook Hold Smoke 56 ...