background image

Page 16

Helios Series

Installation & Users Manual

Connecting 0-10V Control

All 0-10VDC wiring should be done with shielded pair wiring with the shield grounded to earth at the

controller. The pair does not need to be twisted. We particularly recommend this when low end dimming

performance is of high importance as un-shielded analog control wiring runs are susceptible to interference.

Fixture dimming performance is dependant on driver quality. The Helios Series is designed to dim from 100% 

- 10% of maximum intensity.

Connect 2-wire cable to terminals via flexible 

conduit. 

Conduit Entry / Exit

Connecting Emergency Battery and Control (Optional)

A optional battery backup driver in compliance with UL924 and CSA C22.2 no.141 is available. This is 

comprised of a driver/battery and separate bracket. The emergency battery back up can only be utilized on 

recessed mounted units.  Surface mount and cable mounted units are not compatible with the Emergency Bat-

tery back up accessory.

1. Locate bracket to allign with screw 

holes on back of panel.

2. Attach bracket to back of panel.

Summary of Contents for Helios Series

Page 1: ...USER S MANUAL HELIOS_SERIES_USERS_MANUAL_REV_20201204 HELIOS SERIES ...

Page 2: ...lation Users Manual Table Of Contents Preface 3 Important Information 5 FCC Notice 6 Product Warranty 6 Product Overview 8 Installation And Setup 9 Operation 18 Cleaning And Care 19 Troubleshooting 20 Technical Specifications 21 ...

Page 3: ...alquier comentario sug erencia o corrección con respecto a este manual favor de dirijirlo a la oficina de Altman Lighting más cercana Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht Aenderungen sind vorbehalten Alt man Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer die in diesem Handbuch auftreten FürBemerkungen und Verbesserungsvorschlaege oder Vorschlaege i...

Page 4: ...ly engages in research related to product improvement New materials production methods and design refinements are introduced into existing products without notice as a routine expression of the philosophy For this reason any current Altman Lighting product may differ in some respect from its published description but will always equal or exceed the original design specifications unless otherwise n...

Page 5: ...al Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power at the circuit breaker o...

Page 6: ...replacement any part defect due to faulty material or workmanship Under these same terms products with an LED light source shall be warranted for a period of FIVE 5 years and One 1 day Altman warrants for NINETY 90 days any spare part it manufactures On spare parts or products Altman does not manufacture including but not limited to lamps sockets lenses roundels electronics ignitors ballasts etc A...

Page 7: ...29 USA 1 303 500 7072 support altmanlighting com RMA s can also be submtted on line via https www altmanlighting com return materials authorization The return must be within THIRTY 30 days of receiving the RMA from Altman Altman warrants for NINETY 90 days any spare part it manufactures On spare parts or products Altman does not manufacture such as lamps sockets lenses roundels electronics ignitor...

Page 8: ...tant circuit or a relay device It should never be con nected to a dimmer or circuit controlled by a dimmer WARNING The maximum allowable input current is 20 Amps Do not overload circuits Luminaires must be sup plied by a branch circuit protected by a maximum 20 Amp circuit protector Doit être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur Ne surcharge...

Page 9: ...rid Ceiling 1 Take the panel out of the box and protective bag remove protective film 2 Lift the mounting clip on the edge of the panel 3 Turn the mounting clip head 4 Place the panel into the ceiling 5 Check the clips can fasten to the T Bar structure 6 Remove the driver box cover ...

Page 10: ...t hole 8 Insert the cable into the driver box 9 Connect the AC power and the 0 10V signal cable to LED driver if 0 10V control 10 Insert the driver box on the right side of the cover then slide it to the left to hold the cover 11 Re attach the driver cover 12 Complete ...

Page 11: ...nt with Frame 1 Identify the two frame types as illus trated above type A B 2 Attach the two A frames together with one B frame 3 Mount the frame to the ceiling 4 Slide the Panel in to the frame Note Luminaire shown for installation purposes and is not to scale ...

Page 12: ...Page 12 Helios Series Installation Users Manual 6 Affix the second frame with the screws supplied 5 Wire luminaire per wiring instruc tions previously described in this manual ...

Page 13: ...he two frame types as illus trated above type A B 2 Insert the wall plugs into the ceiling and secure the suspension surface fixing to the ceiling 3 Please note the recommended distances for the ceiling fixings 4 Screw the suspension cable to the ceiling fixing 20 47 20 47 16 73 ...

Page 14: ...s Manual 5 Lift the mounting clip on the edge of panel 6 Lock the suspension cable to the clip 7 Adjust the cable length to meet the height requirements 8 Fix the cable to the ceiling 9 Open the knockout holes 10 Remove the driver box cover ...

Page 15: ...ual 11 Insert the cables into driver box 12 Connect the AC mains power and 0 10V dimmable cable to LED Driver 13 Slide the power cover toward the label to secure the power cover 14 Attach the driver cover back with hardware provided 15 Completed ...

Page 16: ...ver quality The Helios Series is designed to dim from 100 10 of maximum intensity Connect 2 wire cable to terminals via flexible conduit Conduit Entry Exit Connecting Emergency Battery and Control Optional A optional battery backup driver in compliance with UL924 and CSA C22 2 no 141 is available This is comprised of a driver battery and separate bracket The emergency battery back up can only be u...

Page 17: ...Page 17 Helios Series Installation Users Manual 3 Attach battery driver to bracket 4 Using appropriate conduit connect wiring as detailed below ...

Page 18: ...evel Power Switch Type 1 Power levels are selectable via the switch located on the driver control box Selecting Color Temperature Selector Switch Type 1 Color temperature is selectable via the switch located on the driver control box Selector Switch Type 2 Power Switch Type 2 ...

Page 19: ...aken with the plastic components because they are much easier to scratch or damage than glass The following is a list of cleaning materials required to care for the Helios Series Lint free lens tissue Lint or powder free gloves A mild soap solution WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the Helios Series These types of cleane...

Page 20: ...ghting Dealer or Service Center DESCRIPTION ISSUE POSSIBLE CAUSE REMEDY No light output Fixture will not produce or output light and connected to power 0 10 Control is set at 0 inten sity 0 10 Control is not connected properly NON DIM version has no power Low light output Fixture produces low light output and connected to power 0 10 Control is set to low setting No power at luminaire Luminaire doe...

Page 21: ...umens Watt Current Draw Current Draw Input Voltage Input Voltage Power Factor Power Factor Cooling Cooling Environment Environment Compliance Compliance Warranty Warranty Support Support Emergency Emergency Corrosion resistant materials and hardware White RAL 9016 0 10V 10 100 or Non Dim On Off 3000K 3 500K 4 300K 120 2x2 20 25 30 Watt Settings 1x4 20 25 30 Watt Settings 2x4 30 35 40 Watt Settings...